Hydropneumatic Tank Minor Loss Coefficient Outflow located in Transient (Physical) Alternative and NO MORE in Physical Alternative
I realize that illogically for Hydro-pneumatic Tank minor loss coefficient outflow located in Transient (Physical) table on the interface such as outlet diameter, ratio of losses, pressure gas preset, and others is however the only one not belongi...
Add control options for VSP pumps and batteries on pressure at suction side
Currently it is only possible to set a VSP pump/battery to regulate on a tank level at its suction side. However, in practice we have systems that regulate pumps on a static suction pressure (mainly booster pump stations) without a tank being pres...
1. User Data Extension – Make all input fields available to create formulas. As it is right now, I cannot use labels of property fields from a manhole (or a TAP) and use it to create a formula for a conduit. It would be great to be able to use tha...
Allow saving and reviewing partial EPS results when “Cannot Solve Equations” occurs
When running Extended Period Simulations (EPS), the occurrence of the “Cannot Solve Equations” error currently causes the entire simulation to fail, with no access to results from the timesteps that were successfully solved prior to the error. It ...
When using VSPs controlled by suction side tanks (or discharge side tanks), the initial tank head becomes the head setting for the VSP. When using Controls, there is no option to define an Action for Tanks to change this head setting, only the Pum...
Incorporate FHWA TechNote 22-061 equations for on-grade side opening inlet calcs.
The current HEC-22 calcs are unconservative. All users would benefit. For example, I ran a calc that showed 0.67 cfs bypass, when the correct calc showed 0.76 cfs.
Hydrant elements should be able to connect to laterals with a tap
Right now, hydrants must either be connected to pipe element representing the pipe lateral or inserted directly into the water mains. Either way requires a junction and pipe split at this location. Hydrants can be connected to a lateral with a tap...
It would be ideal if WaterGEMS had the ability to export the Segments information attributed to water mains in GIS format. This would enable us to display the segments in a GIS web app to serve as a reference for valve isolation tracing. In order ...
Graph Preservation During Models Merge in Openflow Watergems.
Improvement Suggestion – Graph Preservation (or transfer) When Merging Openflow WaterGEMS Models
When merging or combining two OpenFlows WaterGEMS models, hydraulic elements such as pipes, junctions, pumps, tanks, and valves can be transferred s...