For EPS runs, SewerGEMS appears to only provide the "Percent Full (Maximum)" result for wetwells when using the "Explicit (SWMM Solvers)" Active Numerical Solver (under Calculation Options). As consulting engineers, we sometimes receive model that are setup using other solvers (i.e. "GVF-Convex") that we are instructed to not modify but only pull results. It would help to have the "Percent Full (Maximum)" result available when checking system performance without having to change the numerical solver or without having to calculate this value from the available results.