Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
over 2 years ago in Storm and Sewer Products / SewerCAD 1 Needs Review

Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
over 2 years ago in Water Distribution Products / WaterGEMS 0 Reviewed

Saved hydrant flow curves should include chart formatting

When saving a hydrant flow curve in WaterGEMS, it doesn't save the custom formatting of the hydrant curve graph. If I create a hydrant curve and set the y axis to show intervals of 5 or 10 psi, when I save the curve and reopen it, the curve revert...
over 2 years ago in Water Distribution Products / WaterGEMS 0 Reviewed

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.
over 2 years ago in Storm and Sewer Products / SewerGEMS 0 Reviewed

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
over 2 years ago in Water Distribution Products / WaterGEMS 0 Reviewed

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
over 2 years ago in Water Distribution Products / HAMMER 0 Reviewed

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
almost 3 years ago in Water Distribution Products / WaterCAD 0 Reviewed

Network Navigator - Find Isolation Valve Referenced Pipes

To the "Network Trace" Network Navigator Tools, suggest add "Find Pipes Referenced by Isolation Valves" There are use cases for where the user needs to select and edit, delete or report Pipe Elements that are Referenced by Isolation Valve Elements...
almost 3 years ago in Water Distribution Products / WaterCAD 0 Reviewed

Critical Referenced Model Elements: Soft or Hard Deletion Lockout

Some element deletion processes will create invalid, difficult to undo and difficult for some users to diagnose issues when the element is a critical reference element to a separate elements. Examples include: Downstream pipes of Directional Eleme...
almost 3 years ago in Water Distribution Products / WaterCAD 0 Reviewed

SCS dimensionless curves for different durations

I advise to include the possibility for SCS dimensionless curves for 6 and 12 hours events instead of only 24 hours as per current OpenFlows products.
almost 3 years ago in Storm and Sewer Products / SewerGEMS 0 Reviewed