Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

WaterGEMS

Showing 11 of 78

A simply option to create folders for Selection Set

Look, i think that an option to create a folder in selection sets it would be reaaly good. Just a simply folder like in graphs.
11 days ago in Water Distribution Products / WaterGEMS 0 Needs review

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
about 2 months ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
about 2 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
3 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Add a toggle to disable moving elements in stand-alone applications.

It is far too easy to move elements in stand-alone WaterGEMS, such that I frequently move things by accident (thank you for easy undo). It would be nice to have the option to disable moving elements since we're 1:1 integrated with GIS and I rarely...
4 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Customer Meter Demand & Pressure support for Scada Elements

Most of our large customers are measured using smart meters which are present in our Scada System. Please add support for Scada Elements to connect to customer meters directly (demand & pressure).
7 months ago in Water Distribution Products / WaterGEMS 2 Future consideration

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
2 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
9 months ago in Water Distribution Products / WaterGEMS 0 Future consideration

hydrant as target element type in properties of SCADA element

Please make possible to assign SCADA signal with hydrant - for example for pressure. We are making very often measurements on hydrants and now if I would like to assign pressure records to hydrant I have to change hydrant to junction first. After ...
5 months ago in Water Distribution Products / WaterGEMS 0 Future consideration

Access to fields of different objects in one tabular table

In many cases, it is required to access a specific field of a pipe in node tables or vice versa
11 months ago in Water Distribution Products / WaterGEMS 5 Future consideration