Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 78 of 78

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
2 months ago in Water Distribution Products / WaterGEMS 0 Needs review

HAMMER: Transient Results Viewer\Extended Node Data\Hydropneumatic Tank: the pressure or head engineering units indicated as absolute values on the Y axis. Without such mention a gauge value is assumed.

A new user looking for the first time at a pressure or head graph might be fooled by the fact that the Y axis does not mention that the units being graphed are in an absolute value. He or she might think hey I'm ok, minimum gauge value is 10 meter...
9 months ago in Water Distribution Products / HAMMER 1 Future consideration

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
9 months ago in Water Distribution Products / WaterGEMS 0 Future consideration

export all element types at once to shapefiles

export all element types at once to shape files
5 months ago in Storm and Sewer Products / CivilStorm 0 Future consideration

Folders for Selection Sets

Folders for Selection Sets
10 months ago in Water Distribution Products / WaterCAD 0 Planned

Network trace query to trace pressure zones

It would be very useful to have a query similar to "Find connected" that stops at pressure zone boundary elements. The "Pressure Zone" analysis tool kind of does this, but a query that can do this on the fly from a starting element would be really...
10 months ago in Water Distribution Products / WaterCAD 0 Future consideration

Zoom-dependent visibility of background layers

Exactly what title says
10 months ago in Water Distribution Products / WaterCAD 0 Future consideration

Flowmaster Inlet Grates

it would be helpful to be able to analyze inlets that have slanted grates that are slanted in the direction of gutter flow. These grates are commonly used in DOT design as well as private applications. Please see attachment.
2 months ago in Storm and Sewer Products 0 Needs review

SewerGEMS: Grey out unnecessary tools and options in ribbons

SewerGEMS software dynamically hides attributes in the object properties window that are not used at given settings in calculations. However, this approach is not applied to the options and tools visible in the ribbons. Suggestion: Tools and optio...
about 1 year ago in Storm and Sewer Products / SewerGEMS 1 Needs review

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
3 months ago in Water Distribution Products / HAMMER 0 Needs review