Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Introduce a Save-As Functionality on WaterGEMS for ArcGIS Pro.

Introduce a Save-As Functionality on WaterGEMS for ArcGIS Pro, to allow the users to create a copy of the model and maintain all customization (layers, symbology, labels) in the original aprx.
over 1 year ago in Water Distribution Products / WaterGEMS 0 Reviewed

Add the ability to rearrange the order of entries in Selection Sets, Flextables, Profiles, Queries, Scenarios and Alternatives

The functionality of rearranging entries individually is not present in: Selection Sets, FlexTables, Profiles, Queries, Scenarios (on the same level), Alternatives (on the same level) and probably a few that I'm missing. For some of these there is...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Reviewed

Add a “Surge Valve Between Pipes” element with differential pressure (ΔP) control and configurable downstream pressure

In HAMMER/OpenFlows, relief/surge valves are typically modeled as discharging to atmosphere, or with logic that does not adequately represent “in-line” relief valves (between two pipes) whose actuation depends on the pressure differential between ...
9 months ago in Water Distribution Products / HAMMER 0 Reviewed

Hydropneumatic Tank Minor Loss Coefficient Outflow located in Transient (Physical) Alternative and NO MORE in Physical Alternative

I realize that illogically for Hydro-pneumatic Tank minor loss coefficient outflow located in Transient (Physical) table on the interface such as outlet diameter, ratio of losses, pressure gas preset, and others is however the only one not belongi...
3 months ago in Water Distribution Products / HAMMER 0 Reviewed

Add control options for VSP pumps and batteries on pressure at suction side

Currently it is only possible to set a VSP pump/battery to regulate on a tank level at its suction side. However, in practice we have systems that regulate pumps on a static suction pressure (mainly booster pump stations) without a tank being pres...
3 months ago in Water Distribution Products / WaterGEMS 0 Needs Review

Allow Controls to work on Tanks

When using VSPs controlled by suction side tanks (or discharge side tanks), the initial tank head becomes the head setting for the VSP. When using Controls, there is no option to define an Action for Tanks to change this head setting, only the Pum...
4 months ago in Water Distribution Products / WaterGEMS 0 Needs Review

Selecting Upstream Catchments

We asking for a tool in SewerGEMS for directly select connected or upstream catchments to the element of for a specified outfall.
over 3 years ago in Storm and Sewer Products / SewerGEMS 2 Reviewed

Incorporate FHWA TechNote 22-061 equations for on-grade side opening inlet calcs.

The current HEC-22 calcs are unconservative. All users would benefit. For example, I ran a calc that showed 0.67 cfs bypass, when the correct calc showed 0.76 cfs.
4 months ago in Storm and Sewer Products / FlowMaster 1 Needs Review

web-based model viewer

In our sector of the company just me had the software watergems, so it would be awesome if we had a web-based model viewer just to share the results of the models, like pressure zones or headlosses. It would be an huge step for us, we also could u...
about 3 years ago in Water Distribution Products / WaterCAD 0 Reviewed

Snapping Tools in SewerGEMS Standalone

It is very important to provide a Snapping Tools to the SewerGEMS Standalone for better digitizing and allocating element on the other elements, for example Tap element to the pipe.
over 3 years ago in Storm and Sewer Products / SewerGEMS 3 Reviewed