Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Storm and Sewer Products

Showing 92 of 173

OpenFlows - SewerCAD/GEMS Ideas

1. User Data Extension – Make all input fields available to create formulas. As it is right now, I cannot use labels of property fields from a manhole (or a TAP) and use it to create a formula for a conduit. It would be great to be able to use tha...
7 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Add Capability to Input Custom Grate Area and Perimeter and Report Output Grate Area and Perimeter

Even though grate input parameters such as grate length, grate width, and clogging factor already exist, the resulting grate area and perimeter used in both weir and orifice calculations are not reported as calculation outputs. The end user cannot...
7 days ago in Storm and Sewer Products / StormCAD 0 Needs review

Spread Analysis of a Non-Inlet Location

Establish a means to complete a spread analysis at points of interest which are not inlets. Example 1: Determination of spread width at the end of a barrier/curb where there is no inlet. Example 2: Determination of spread width at a change in shou...
7 days ago in Storm and Sewer Products / StormCAD 0 Needs review

Show Utilities Crossings on Profile

Objective: To develop a software solution that seamlessly integrates OpenFlows with OpenRoads, facilitating the generation of utility profiles (StormWater, WasteWater, WaterSupply, etc.) and ensuring efficient crossings with other pipes and networ...
about 2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Improved Annotation Placement on Drawings

Problem: Overlapping text labels on manholes makes drawings hard to read. Suggestion: Implement smart label placement to avoid overlap, and use arrows to connect distant labels to their respective manholes.
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Manhole Spacing Based on Pipe Diameter

Problem: The spacing between manholes isn’t automatically related to pipe diameter. Suggestion: Allow the program to adjust spacing between manholes based on the pipe diameter.
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Link Population Density from GIS to Network Design

Problem: Current population data from GIS is not automatically used for calculating wastewater flow. Suggestion: Integrate GIS-based population density data with hydraulic calculations, including projections for future urban expansion.
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Generate Network Routing Scenarios Based on Road Slopes

Problem: Network routing is based solely on the drawn layout, without considering road slopes or the optimal path. Suggestion: Introduce a feature that suggests multiple routing scenarios based on road slopes and shortest paths to the lift station.
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Display Natural Ground Elevations with Color Gradients

Problem: It’s difficult to visually identify high and low ground areas during planning. Suggestion: Display natural ground elevations using color gradients to highlight high areas as potential starting points for gravity lines, and low areas as po...
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Automated Extraction and Layout of Profiles

Problem: Extracting profiles and placing them on sheets with proper labeling is a time-intensive manual process. Suggestion: Provide an option to automatically extract profiles, arrange them on sheets, and assign appropriate numbers within the sof...
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review