REGARDING WATER LEVEL VARIATION IN HYDRONEUMTIC TANK

SIR I HAVE SEEN THAT TRACKING OF WATER LEVEL OSCILLATION HAS NOT BEEN INCORPORATED IN HAMMER. INSTEAD GAS VOLUME VARIATION IS AVAILABLE. BUT IF OUR EXPERTS CAN IMPLEMENT THE WATER LEVEL VARIATION, IT IS SO HELPFUL.
over 1 year ago in Water Distribution Products / HAMMER 1 Already Exists

turbine load acceptance followed by load rejection

sir the above case is so important in case of surge protection of tail race tunnel and head race tunnel. Also, now a days most of the hydropower plants, the surge tank has been replaced with SURGE GALLERY (IT IS JUST LIKE LONG PIPE OF HAVING DIFFR...
over 1 year ago in Water Distribution Products / HAMMER 0 Needs Review

Associate property connection with its conduit

Currently, SewerGEMS allows reports on the lateral associated with the property connection and tap, and the tap associated with the conduit. In Latin America, the sewer cleanout box (property connection) is generally associated with a service numb...
over 1 year ago in Storm and Sewer Products / SewerGEMS 1 Reviewed

Keyboard Shortcuts and keybinds

As it stands today, neither SewerGEMS or WaterCAD have any useful keyboard shortcuts or keyboard control, besides pressing Enter or Escape. Some ideas: Control the viewport with WASD keys Using the program you have a LOT of mouse movement, especia...
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Reviewed

Graph of mass (real) air flow through an air valve

It would be better if the detailed airflow graph would show the "mass air flow rate" and thus the user can confirm whether real air volume was expelled from the air valve to the atmosphere or not. The current situation in which we watch "momentary...
over 1 year ago in Water Distribution Products / HAMMER 0 Reviewed

When a surge relief valve dumps to a reservoir, can an external pressure input option be added to the software?

When a surge relief valve dumps to a reservoir, can an external pressure input option be added to the software? Other softwares for transient analysis have this input.
over 1 year ago in Water Distribution Products / HAMMER 1 Reviewed

Fix FCV calculation routine and/or add calculation option

Background info (including Jesse Dringoli's response) can be found here. The Flow Control Valve (FCV) calculations in WaterGEMS currently allows the calculated Cv value to exceed the fully open Cv value. The link to the Forum post above includes m...
over 1 year ago in Water Distribution Products / WaterGEMS 1 Reviewed

Adicionar el código de las tuberías a las elevaciones inversas en el dibujo del perfil y que se visualicen en este nodo

La utilidad es que se podría leer directamente del perfil las elevaciones inversas y verificar que las descargas de las tuberías entrantes al nodo lo hagan con descarga libre y no se interfieran entre estas. Esto beneficiaria a los diseñadores par...
over 1 year ago in Storm and Sewer Products / SewerGEMS 1 Reviewed

Angle Readout for Node Angle Flex Tables for Stormwater Nodes to be in Degrees, Minutes Seconds. Not Degrees or Minutes or Seconds.

Setout Instruments do not read decimal degrees. It is incorrect to specify angles in just Minutes, or Seconds
over 3 years ago in Storm and Sewer Products / CivilStorm 0 Reviewed

Add Pipe Status (Calculated) to Quick Graphs

This will provide a visual test to make sure pipe controls are working as anticipated and help troubleshoot model issues that may or may not be caused by pipe controls.
over 3 years ago in Water Distribution Products / WaterCAD 0 Reviewed