Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

CivilStorm

Showing 13 of 103

Calculate catchment area runoff without an outflow node

Applicable to CivilStorm, StormCADD, and PondPack. Sometimes we only want to calculate the runoff generated by a catchment area. However, catchment areas do not calculate runoff unless a outflow node is specified. White it's not terribly difficult...
1 day ago in Storm and Sewer Products / CivilStorm 0 Needs review

Perform only necessary computations

Applicable to CivilStorm, StormCAD, and probably PondPack. Sometimes we only use the software to perform certain computations. For example, we are wanting to analyze the storm sewer. The drainage areas would be connected to catchbasin elements. Ho...
1 day ago in Storm and Sewer Products / CivilStorm 0 Needs review

Make it easier to integrate with projectwise

Currently, to allow CivilStorm (and I'm assuming StormCAD/PondPak) to integrate with ProjectWise, we have to edit an XML file following this guidance: https://bentleysystems.service-now.com/community?id=kb_article_view&sysparm_article=KB005824...
1 day ago in Storm and Sewer Products / CivilStorm 0 Needs review

Conduit Shape Enhancement (Circular Open Channel)

Create a shape where the semi-circle is at the bottom of the channel in order to model a circular open channel section.
over 1 year ago in Storm and Sewer Products / CivilStorm 1 Future consideration

export all element types at once to shapefiles

export all element types at once to shape files
12 months ago in Storm and Sewer Products / CivilStorm 0 Future consideration

Add the PondPack Pond Estimated Storage calculator to OpenFlows CivilStorm

Add the PondPack Pond Estimated Storage calculator to OpenFlows CivilStorm. There is no comparable analysis tool in CivilStorm.
over 1 year ago in Storm and Sewer Products / CivilStorm 1 Already exists

Have parametric cells for nodes

Parametric cells for nodes will enable the software to increase the size of the node when required by capacity calculations. It can also change the node size when required to accommodate larger pipes. This will also reduce the size of the cell lib...
over 1 year ago in Storm and Sewer Products / CivilStorm 1 Needs review

Make sharing Shared FlexTables easier

This idea is relevant to all drainage-related products, especially OpenRoads Drainage. Currently the way to share Shared FlexTables across laptops requries users to copy a FlexTables XML folder into a very specific folder on their Cdrive. It would...
over 1 year ago in Storm and Sewer Products / CivilStorm 0 Future consideration

Add back-drop height property

Please add a property to all the chambers including both catchbasins and manhole which specify the back drop height (multiple values if we have multiple incoming pipes)
over 1 year ago in Storm and Sewer Products / CivilStorm 1 Needs review

Angle Readout for Node Angle Flex Tables for Stormwater Nodes to be in Degrees, Minutes Seconds. Not Degrees or Minutes or Seconds.

Setout Instruments do not read decimal degrees. It is incorrect to specify angles in just Minutes, or Seconds
over 1 year ago in Storm and Sewer Products / CivilStorm 0 Needs review