Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Saved hydrant flow curves should include chart formatting

When saving a hydrant flow curve in WaterGEMS, it doesn't save the custom formatting of the hydrant curve graph. If I create a hydrant curve and set the y axis to show intervals of 5 or 10 psi, when I save the curve and reopen it, the curve revert...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Angle Readout for Node Angle Flex Tables for Stormwater Nodes to be in Degrees, Minutes Seconds. Not Degrees or Minutes or Seconds.

Setout Instruments do not read decimal degrees. It is incorrect to specify angles in just Minutes, or Seconds
almost 2 years ago in Storm and Sewer Products / CivilStorm 0 Needs review

Add Pipe Status (Calculated) to Quick Graphs

This will provide a visual test to make sure pipe controls are working as anticipated and help troubleshoot model issues that may or may not be caused by pipe controls.
almost 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

Access to fields of different objects in one tabular table

In many cases, it is required to access a specific field of a pipe in node tables or vice versa
almost 2 years ago in Water Distribution Products / WaterGEMS 5 Future consideration

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.
about 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
about 1 year ago in Water Distribution Products / HAMMER 0 Needs review

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
over 1 year ago in Water Distribution Products / WaterCAD 0 Needs review

Network Navigator - Find Isolation Valve Referenced Pipes

To the "Network Trace" Network Navigator Tools, suggest add "Find Pipes Referenced by Isolation Valves" There are use cases for where the user needs to select and edit, delete or report Pipe Elements that are Referenced by Isolation Valve Elements...
over 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration