Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Improve Reporting for Drainage Reports

Overall, throughout the years I've been disappointed with the report compilation that Bentley generates. It's currently very cumbersome to generate a readable report of the computations so that they can be included in drainage reports. The "Custom...
about 2 years ago in Storm and Sewer Products 2 Needs Review

Adding Bulletin 75 to the Engineering Libraries

Bulletin 70, 71 and circular 173 are all outdated. Bulletin 75 needs to be incorporated for accurate results in Illinois.
about 1 year ago in Storm and Sewer Products / CivilStorm 0 Reviewed

Option to lock down and only able to save files in ProjectWise

Lock down to only have the ability to save files in ProjectWise will give organizations better control of files being properly stored and available to other users
about 1 year ago in Water Distribution Products / HAMMER 0 Reviewed

Option to lock down and only able to save files in ProjectWise

Lock down to only have the ability to save files in ProjectWise will give organizations better control of files being properly stored and available to other users
about 1 year ago in OpenFlows FLOOD 0 Needs review

Open on selection for controls table

Sometimes you need to look at the controls for several facilities at once (e.g., two different pump stations that serve the same zone), and don't want to open the full controls table. It would be convenient to have an option to "open on selection"...
about 2 years ago in Water Distribution Products / WaterCAD 0 Reviewed

Selecting Feature Level on application startup

It is not easy or intuitive for users to select the correct Feature Level based on their expected use of the software and we are concerned that the wrong daily use gets charged
about 1 year ago in Water Distribution Products / HAMMER 0 Reviewed

Add Additional Local Fire Flow Constraint Options

For fire flow analyses, there should be additional constraint options that allow the results of a specified residual node to be output for each fire flow node (including pressure and residual pressure). This would allow for direct comparison of hy...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs Review

Add "Copy" button to surge profile graph in Hammer

The TIME SERIES and EXTENDED NOTE DATA tabs have "Copy" buttons for graphs displayed. However, the PROFILE tab does not have this option, and the user needs to take a screenshot of the profile manually. Please add this capability to PROFILE graphs.
about 1 year ago in Water Distribution Products / HAMMER 0 Needs Review

View total junction demand in the properties window

Be able to see total demand listed in the junction properties window or in the Flex tables without opening the demand collection.
over 3 years ago in Water Distribution Products / WaterCAD 1 Reviewed

export to epanet

I have a problem when I export the model from watercad (in CMH) to Epanet the numbers are changed to L/S, even if i choose CMH in the epanet. For example: in watercad it is 1440 CMH while in the epanet it is still stays 400 even if the units are s...
about 2 years ago in Water Distribution Products / WaterCAD 1 Reviewed