Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 103 of 103

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
10 months ago in Water Distribution Products / WaterCAD 0 Needs review

Network Navigator - Find Isolation Valve Referenced Pipes

To the "Network Trace" Network Navigator Tools, suggest add "Find Pipes Referenced by Isolation Valves" There are use cases for where the user needs to select and edit, delete or report Pipe Elements that are Referenced by Isolation Valve Elements...
10 months ago in Water Distribution Products / WaterCAD 0 Future consideration

Critical Referenced Model Elements: Soft or Hard Deletion Lockout

Some element deletion processes will create invalid, difficult to undo and difficult for some users to diagnose issues when the element is a critical reference element to a separate elements. Examples include: Downstream pipes of Directional Eleme...
10 months ago in Water Distribution Products / WaterCAD 0 Needs review

SCS dimensionless curves for different durations

I advise to include the possibility for SCS dimensionless curves for 6 and 12 hours events instead of only 24 hours as per current OpenFlows products.
11 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

2d module hot file

For 2d calculation, the option for hot start should be added, especially that this kind of calculations takes long time.
11 months ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

hydrant as target element type in properties of SCADA element

Please make possible to assign SCADA signal with hydrant - for example for pressure. We are making very often measurements on hydrants and now if I would like to assign pressure records to hydrant I have to change hydrant to junction first. After ...
12 months ago in Water Distribution Products / WaterGEMS 0 Future consideration

Built-in tool to graphically display custom turbine curves / characteristics in HAMMER.

Tool to display custom turbine curves / characteristics in hill chart form or otherwise, to allow checking input data for correctness, accuracy, sense. To assist in diagnosing issues when using custom turbine curves. To allow comparing different t...
about 1 year ago in Water Distribution Products / HAMMER 0 Future consideration

Dashed/dotted line type

Dashed or dotted linetype option for pipe elements to distinguish the existing pipes from future/planned pipes or vice versa.
about 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

Allow reduction of MSX constituent concentration via [SOURCES]

No idea if this can actually be done because it's not currently a feature within MSX however it was suggested I add it here so here it is. Basically MSX only allows for adding constituents through the [SOURCES] controls, but it doesn't provide any...
about 1 year ago in Water Distribution Products / WaterCAD 0 Needs review

Grid regeneration

The message prompting before every simulation computing is ambiguous - is it necessary to regenerate grid each time I want to compute model? Probably not if the grid wasn't changed.
over 2 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review