Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Water Distribution Products

Showing 87 of 187

Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Saved hydrant flow curves should include chart formatting

When saving a hydrant flow curve in WaterGEMS, it doesn't save the custom formatting of the hydrant curve graph. If I create a hydrant curve and set the y axis to show intervals of 5 or 10 psi, when I save the curve and reopen it, the curve revert...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
over 1 year ago in Water Distribution Products / HAMMER 0 Needs review

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Needs review

Network Navigator - Find Isolation Valve Referenced Pipes

To the "Network Trace" Network Navigator Tools, suggest add "Find Pipes Referenced by Isolation Valves" There are use cases for where the user needs to select and edit, delete or report Pipe Elements that are Referenced by Isolation Valve Elements...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

Critical Referenced Model Elements: Soft or Hard Deletion Lockout

Some element deletion processes will create invalid, difficult to undo and difficult for some users to diagnose issues when the element is a critical reference element to a separate elements. Examples include: Downstream pipes of Directional Eleme...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Needs review

Built-in tool to graphically display custom turbine curves / characteristics in HAMMER.

Tool to display custom turbine curves / characteristics in hill chart form or otherwise, to allow checking input data for correctness, accuracy, sense. To assist in diagnosing issues when using custom turbine curves. To allow comparing different t...
almost 2 years ago in Water Distribution Products / HAMMER 0 Future consideration

Allow reduction of MSX constituent concentration via [SOURCES]

No idea if this can actually be done because it's not currently a feature within MSX however it was suggested I add it here so here it is. Basically MSX only allows for adding constituents through the [SOURCES] controls, but it doesn't provide any...
about 2 years ago in Water Distribution Products / WaterCAD 0 Needs review

Automatically calculate Volume (Inactive)

I'm willing to bet the majority of people don't realise that the volume of water between 'Base' and 'Minimum' is NOT included in water age and constituent modelling unless they manually specify 'Volume (Inactive)'. I did figure this out over a yea...
about 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration