Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Water Distribution Products

Showing 51 of 103

Network trace query to trace pressure zones

It would be very useful to have a query similar to "Find connected" that stops at pressure zone boundary elements. The "Pressure Zone" analysis tool kind of does this, but a query that can do this on the fly from a starting element would be really...
over 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

Zoom-dependent visibility of background layers

Exactly what title says
over 1 year ago in Water Distribution Products / WaterCAD 0 Planned

Customer Meter Demand & Pressure support for Scada Elements

Most of our large customers are measured using smart meters which are present in our Scada System. Please add support for Scada Elements to connect to customer meters directly (demand & pressure).
about 1 year ago in Water Distribution Products / WaterGEMS 2 Future consideration

export to epanet

I have a problem when I export the model from watercad (in CMH) to Epanet the numbers are changed to L/S, even if i choose CMH in the epanet. For example: in watercad it is 1440 CMH while in the epanet it is still stays 400 even if the units are s...
4 months ago in Water Distribution Products / WaterCAD 0 Future consideration

PRV that can control pressure at a remote node

Some hydraulic modelling software allows users to specify a remote node which as the target for PRV pressure settings. For example a PRV at the entrance of a zone might modulate so that the pressure doesn't exceed 30m at the node in the zone with ...
4 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Add a toggle to disable moving elements in stand-alone applications.

It is far too easy to move elements in stand-alone WaterGEMS, such that I frequently move things by accident (thank you for easy undo). It would be nice to have the option to disable moving elements since we're 1:1 integrated with GIS and I rarely...
11 months ago in Water Distribution Products / WaterGEMS 0 Future consideration

web-based model viewer

In our sector of the company just me had the software watergems, so it would be awesome if we had a web-based model viewer just to share the results of the models, like pressure zones or headlosses. It would be an huge step for us, we also could u...
over 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

HAMMER: Transient Results Viewer\Extended Node Data\Hydropneumatic Tank: the pressure or head engineering units indicated as absolute values on the Y axis. Without such mention a gauge value is assumed.

A new user looking for the first time at a pressure or head graph might be fooled by the fact that the Y axis does not mention that the units being graphed are in an absolute value. He or she might think hey I'm ok, minimum gauge value is 10 meter...
over 1 year ago in Water Distribution Products / HAMMER 1 Future consideration

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review