[Copy] Allow the road slope to exceed the gutter cross slope

My state agency commonly uses gutters with a 4% cross slope. The maximum superelevation rate is 7%. The gutter slope stays at 4% in this situation. Spread does not compute in this scenario because "A depressed gutter must have a Gutter Cross Slope...
12 months ago in Storm and Sewer Products 0 Needs review

export all element types at once to shapefiles

export all element types at once to shape files
about 2 years ago in Storm and Sewer Products / CivilStorm 0 Future consideration

SewerGEMS: Implementing tools for model skeletonization

The SewerGEMS development currently has no module, function or option to simplify the sewer network model. Such a tool is present implemented in the WaterGEMS software. It is clear that simplification on the sewer network may be more difficult to ...
over 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

SewerGEMS: Grey out unnecessary tools and options in ribbons

SewerGEMS software dynamically hides attributes in the object properties window that are not used at given settings in calculations. However, this approach is not applied to the options and tools visible in the ribbons. Suggestion: Tools and optio...
over 2 years ago in Storm and Sewer Products / SewerGEMS 1 Needs review

Perform only necessary computations

Applicable to CivilStorm, StormCAD, and probably PondPack. Sometimes we only use the software to perform certain computations. For example, we are wanting to analyze the storm sewer. The drainage areas would be connected to catchbasin elements. Ho...
about 1 year ago in Storm and Sewer Products / CivilStorm 2 Needs review

Add Capability to Input Custom Grate Area and Perimeter and Report Output Grate Area and Perimeter

Even though grate input parameters such as grate length, grate width, and clogging factor already exist, the resulting grate area and perimeter used in both weir and orifice calculations are not reported as calculation outputs. The end user cannot...
7 months ago in Storm and Sewer Products / StormCAD 0 Needs review

Improve Reporting for Drainage Reports

Overall, throughout the years I've been disappointed with the report compilation that Bentley generates. It's currently very cumbersome to generate a readable report of the computations so that they can be included in drainage reports. The "Custom...
about 1 year ago in Storm and Sewer Products 2 Needs review

Add a toggle to disable moving elements in stand-alone applications.

It is far too easy to move elements in stand-alone WaterGEMS, such that I frequently move things by accident (thank you for easy undo). It would be nice to have the option to disable moving elements since we're 1:1 integrated with GIS and I rarely...
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

Make sharing Shared FlexTables easier

This idea is relevant to all drainage-related products, especially OpenRoads Drainage. Currently the way to share Shared FlexTables across laptops requries users to copy a FlexTables XML folder into a very specific folder on their Cdrive. It would...
over 2 years ago in Storm and Sewer Products / CivilStorm 1 Future consideration

Hydraulic toolbox

incorporate the FHWA hydraulic toolbox into the product for quick calcs, channel lining, culvert outlet protection, etc... Could be an add on that can pull the data out of the model.
8 months ago in Storm and Sewer Products / StormCAD 0 Needs review