Automated Extraction and Layout of Profiles

Problem: Extracting profiles and placing them on sheets with proper labeling is a time-intensive manual process. Suggestion: Provide an option to automatically extract profiles, arrange them on sheets, and assign appropriate numbers within the sof...
9 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

SewerGEMS: Add Wetwell Percent Full (Maximum) Result for SewerCAD/SewerGEMS Solvers

For EPS runs, SewerGEMS appears to only provide the "Percent Full (Maximum)" result for wetwells when using the "Explicit (SWMM Solvers)" Active Numerical Solver (under Calculation Options). As consulting engineers, we sometimes receive model that...
4 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Add a flex table and/or create a summary report (PDF) containing the kinematic flow variables for TR-55 or HEC-22 methods.

The required variables are user entered. None currently are retrieved from the model. Most variables are user defined. Slope and segment values could be populated from the model. We need a table or report for checking the calcs and for legal archi...
9 months ago in Storm and Sewer Products / StormCAD 0 Needs review

Make it easier to integrate with projectwise

Currently, to allow CivilStorm (and I'm assuming StormCAD/PondPak) to integrate with ProjectWise, we have to edit an XML file following this guidance: https://bentleysystems.service-now.com/community?id=kb_article_view&sysparm_article=KB005824...
about 1 year ago in Storm and Sewer Products / CivilStorm 0 Needs review

initial abstraction ratio

State agency requires initial abstraction ratio (Ia/s) to be 0.05 for RPv events. software assumes default value of 0.2, and the user can't change it. We need to have an option to adjust initial abstraction ratio for specific scenarios of SCS unit...
9 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Customer Meter Demand & Pressure support for Scada Elements

Most of our large customers are measured using smart meters which are present in our Scada System. Please add support for Scada Elements to connect to customer meters directly (demand & pressure).
about 2 years ago in Water Distribution Products / WaterGEMS 3 Future consideration

Conduit Shape Enhancement (Circular Open Channel)

Create a shape where the semi-circle is at the bottom of the channel in order to model a circular open channel section.
over 2 years ago in Storm and Sewer Products / CivilStorm 1 Future consideration

NRCS/SCS Peak Discharge

Currently I use ORD and have to use Civilstorm license to run SCS hydrology. I don't really need the full hydrograph for all projects. It would be to have get peak discharge using the stormCAD license inside ORD.
10 months ago in Storm and Sewer Products / StormCAD 0 Needs review

WaterGems Quick Start Lessons

Missing step in quick start guide: In step 2, point 9 the lesson suggested that simply right-clicking in the drawing pane would let you add a reservoir. In reality, you needed to first click on the Pipe icon. After doing this, the right-click cont...
5 months ago in Water Distribution Products / WaterGEMS 0 Planned

[Copy] Make the Drainage Catch Basin Grate Perimeter and Open Area variables reportable

Some DOTs require input of an exact values for catch basin grate open area for orifice flow and catch basin grate perimeter for weir flow. ORD would consider these as calculated values, not inputs. These are not ORD outputs and are hidden from the...
6 months ago in Storm and Sewer Products 0 Needs review