Showing 88 of 157

Calculate the difference between the conduit invert stop and the downstream manhole invert level (Add a new field in conduit properties)

it will be useful for whom want to know if a weir is required to be added into the downstream manhole (in case the manhole has more then one weir)
almost 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

adding Model name and # of nodes/pipes to usage report

In order to have better visibility on the work done and distribute the cost charging among different projects, it would be nice to have the below additional into to the e365 open flows product usage: Number of actual model nodes/pipes Model File N...
8 months ago in Storm and Sewer Products / SewerGEMS 1 Needs review

Make sharing Shared FlexTables easier

This idea is relevant to all drainage-related products, especially OpenRoads Drainage. Currently the way to share Shared FlexTables across laptops requries users to copy a FlexTables XML folder into a very specific folder on their Cdrive. It would...
almost 2 years ago in Storm and Sewer Products / CivilStorm 0 Future consideration

The 2D model does not recognize the assignment of LID. Implementation is suggested.

El modelo 2D no reconoce la asignación de LID. Se sugiere la implementación. Es importante simular inundaciones y verificar el comportamiento del alcantarillado al aplicar soluciones de drenaje sostenible.
10 months ago in Storm and Sewer Products / SewerGEMS 1 Needs review

add Grate Width in utility Property

add Grate Width in Utility Property. (See Attachment)
over 1 year ago in Storm and Sewer Products / StormCAD 0 Future consideration

Complex Spread Section

Need the function same as Geopak where the user be able to input/use multiple shoulder and road section. (See attachment)
over 1 year ago in Storm and Sewer Products / StormCAD 0 Future consideration

element property interfacing upgrade

This feature should address pipes start/stop and not the manhole invert incase of a drop at the downstream manhole.
10 months ago in Storm and Sewer Products / SewerCAD 0 Needs review

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
11 months ago in Storm and Sewer Products / SewerCAD 0 Needs review

Angle Readout for Node Angle Flex Tables for Stormwater Nodes to be in Degrees, Minutes Seconds. Not Degrees or Minutes or Seconds.

Setout Instruments do not read decimal degrees. It is incorrect to specify angles in just Minutes, or Seconds
almost 2 years ago in Storm and Sewer Products / CivilStorm 0 Needs review

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.