Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Water Distribution Products

Showing 67 of 146

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
about 1 year ago in Water Distribution Products / HAMMER 0 Needs review

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
about 1 year ago in Water Distribution Products / WaterCAD 0 Needs review

Network Navigator - Find Isolation Valve Referenced Pipes

To the "Network Trace" Network Navigator Tools, suggest add "Find Pipes Referenced by Isolation Valves" There are use cases for where the user needs to select and edit, delete or report Pipe Elements that are Referenced by Isolation Valve Elements...
about 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

Critical Referenced Model Elements: Soft or Hard Deletion Lockout

Some element deletion processes will create invalid, difficult to undo and difficult for some users to diagnose issues when the element is a critical reference element to a separate elements. Examples include: Downstream pipes of Directional Eleme...
about 1 year ago in Water Distribution Products / WaterCAD 0 Needs review

hydrant as target element type in properties of SCADA element

Please make possible to assign SCADA signal with hydrant - for example for pressure. We are making very often measurements on hydrants and now if I would like to assign pressure records to hydrant I have to change hydrant to junction first. After ...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Future consideration

Built-in tool to graphically display custom turbine curves / characteristics in HAMMER.

Tool to display custom turbine curves / characteristics in hill chart form or otherwise, to allow checking input data for correctness, accuracy, sense. To assist in diagnosing issues when using custom turbine curves. To allow comparing different t...
over 1 year ago in Water Distribution Products / HAMMER 0 Future consideration

Allow reduction of MSX constituent concentration via [SOURCES]

No idea if this can actually be done because it's not currently a feature within MSX however it was suggested I add it here so here it is. Basically MSX only allows for adding constituents through the [SOURCES] controls, but it doesn't provide any...
over 1 year ago in Water Distribution Products / WaterCAD 0 Needs review

Automatically calculate Volume (Inactive)

I'm willing to bet the majority of people don't realise that the volume of water between 'Base' and 'Minimum' is NOT included in water age and constituent modelling unless they manually specify 'Volume (Inactive)'. I did figure this out over a yea...
over 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

Add the calculated Reynolds number to the viewable results

I know that Reynolds number is calculated in the background of the model.It'd be really interesting to see what it is throughout the network at any given time to help understand whether/when the pipe is in turbulent vs laminar flow
over 1 year ago in Water Distribution Products / WaterCAD 1 Will not implement