Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Bulk Exporting of Results

Need ability to export results for all scenarios under a chosen scenario with the same given parameters. This can reduce dozens of individual, timely exports into a single export. Or at a larger scale can reduce hundreds of exports down to dozens.
over 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

Color Coding (color/size) a selection set without linking to a Field Name

Quite often I would like to color code a particular set of elements and when I do that I have to choose a Field Name which isn't always relevant. Let's say I want to highlight (color code, color/size) a set of junctions manually picked in my model...
over 2 years ago in Water Distribution Products / WaterCAD 2 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Totalizing Flow Meters in FlexTables

The totalizing flow meter tool is useful, but I would like to be able to get that information without having to look at elements one at a time. It would be nice if the totalizing flow meter would be calculated as a function of the element and coul...
10 months ago in Water Distribution Products / WaterCAD 0 Needs review

Network Navigator Review Pipe Split Candidates - Ignore Customer Meters

Customer Meters are not a valid Element to Split Pipes with and should not be output in the Network Navigator Review Pipe Split Candidates. Customer Meters only exist on the upstream end of 1 or 0 Laterals.
almost 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

hydrant as target element type in properties of SCADA element

Please make possible to assign SCADA signal with hydrant - for example for pressure. We are making very often measurements on hydrants and now if I would like to assign pressure records to hydrant I have to change hydrant to junction first. After ...
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

Create a valve that allows linear reduction of flow depending on closing and create a valve that has a trigger to start closing when a certain pressure is reached.

For modeling irrigation systems, cutting-edge elements such as hydrants/valves have closing rules that not only take time into consideration, but also pressure as a trigger. Furthermore, these valves have linear flow characteristics.
11 months ago in Water Distribution Products / HAMMER 0 Needs review

Allow properties of multiple elements to be edited from properties tab

Useful to be able to edit all properties for multiple elements in the properties tab. Other similar software have these capabilities. This would allow streamlining some of the editing. Also, consider allowing all properties to be edited for multip...
12 months ago in Water Distribution Products / WaterCAD 0 Needs review