Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 121

Angle Readout for Node Angle Flex Tables for Stormwater Nodes to be in Degrees, Minutes Seconds. Not Degrees or Minutes or Seconds.

Setout Instruments do not read decimal degrees. It is incorrect to specify angles in just Minutes, or Seconds
about 2 years ago in Storm and Sewer Products / CivilStorm 0 Needs review

The 2D model does not recognize the assignment of LID. Implementation is suggested.

El modelo 2D no reconoce la asignación de LID. Se sugiere la implementación. Es importante simular inundaciones y verificar el comportamiento del alcantarillado al aplicar soluciones de drenaje sostenible.
about 1 year ago in Storm and Sewer Products / SewerGEMS 1 Needs review

element property interfacing upgrade

This feature should address pipes start/stop and not the manhole invert incase of a drop at the downstream manhole.
about 1 year ago in Storm and Sewer Products / SewerCAD 0 Needs review

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
about 1 year ago in Storm and Sewer Products / SewerCAD 0 Needs review

Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Saved hydrant flow curves should include chart formatting

When saving a hydrant flow curve in WaterGEMS, it doesn't save the custom formatting of the hydrant curve graph. If I create a hydrant curve and set the y axis to show intervals of 5 or 10 psi, when I save the curve and reopen it, the curve revert...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
over 1 year ago in Water Distribution Products / HAMMER 0 Needs review

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
over 1 year ago in Water Distribution Products / WaterCAD 0 Needs review