Snapping Tools in SewerGEMS Standalone

It is very important to provide a Snapping Tools to the SewerGEMS Standalone for better digitizing and allocating element on the other elements, for example Tap element to the pipe.
about 2 years ago in Storm and Sewer Products / SewerGEMS 3 Needs review

Reorganize Order of Scenarios

Applicable to all CivilStorm/StormCAD/PondPack/OpenRoads Drainage products. It would b nice to be able to reorganize the scenarios (the ones on the same hierarchy level). Currently, the scenarios are organized in the order that they are created. B...
3 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

initial abstraction ratio

State agency requires initial abstraction ratio (Ia/s) to be 0.05 for RPv events. software assumes default value of 0.2, and the user can't change it. We need to have an option to adjust initial abstraction ratio for specific scenarios of SCS unit...
3 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Bentley HAMMER batch compute option to run scenarios concurrently rather than consecutively

Hi Bentley Team, HAMMER currently runs batch computed scenarios sequentially. For complex models with multiple scenarios this often results in computations running overnight or even over several days to complete a batch of several scenarios. If po...
about 2 years ago in Water Distribution Products / HAMMER 3 Future consideration

Conduit Shape Enhancement (Circular Open Channel)

Create a shape where the semi-circle is at the bottom of the channel in order to model a circular open channel section.
about 2 years ago in Storm and Sewer Products / CivilStorm 1 Future consideration

Perform only necessary computations

Applicable to CivilStorm, StormCAD, and probably PondPack. Sometimes we only use the software to perform certain computations. For example, we are wanting to analyze the storm sewer. The drainage areas would be connected to catchbasin elements. Ho...
8 months ago in Storm and Sewer Products / CivilStorm 1 Needs review

Tools that assist in automating calibration

A tool that streamlines the iterative process of calibrating a model. Allows the user to input upper and lower values for parameters such as %Imperviousness, Dstorage, RTK, etc. The software would then iterate or use a genetic algorithm to assist ...
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

REGARDING WATER LEVEL VARIATION IN HYDRONEUMTIC TANK

SIR I HAVE SEEN THAT TRACKING OF WATER LEVEL OSCILLATION HAS NOT BEEN INCORPORATED IN HAMMER. INSTEAD GAS VOLUME VARIATION IS AVAILABLE. BUT IF OUR EXPERTS CAN IMPLEMENT THE WATER LEVEL VARIATION, IT IS SO HELPFUL.
4 months ago in Water Distribution Products / HAMMER 1 Already exists

turbine load acceptance followed by load rejection

sir the above case is so important in case of surge protection of tail race tunnel and head race tunnel. Also, now a days most of the hydropower plants, the surge tank has been replaced with SURGE GALLERY (IT IS JUST LIKE LONG PIPE OF HAVING DIFFR...
4 months ago in Water Distribution Products / HAMMER 0 Needs review