Storm and Sewer Products

Calculate the difference between the conduit invert stop and the downstream manhole invert level (Add a new field in conduit properties)

it will be useful for whom want to know if a weir is required to be added into the downstream manhole (in case the manhole has more then one weir)
over 3 years ago in Storm and Sewer Products / SewerGEMS 1 Reviewed

[Copy] Make the Drainage Catch Basin Grate Perimeter and Open Area variables reportable

Some DOTs require input of an exact values for catch basin grate open area for orifice flow and catch basin grate perimeter for weir flow. ORD would consider these as calculated values, not inputs. These are not ORD outputs and are hidden from the...
about 1 year ago in Storm and Sewer Products 0 Needs Review

StormCAD dynamic links to Civil 3D

For StormCAD it would be very helpful to also have a dynamic link between Civil 3D stormwater pipes and StormCAD pipes. We have to run two models essentially and there is a lot of translating data from one model into the other and time spend makin...
over 2 years ago in Storm and Sewer Products / StormCAD 0 Needs Review

PondPack Import Catchment Areas

The most helpful thing for how I use PondPack would be the ability to import catchment areas from CAD polyline work and maybe hatches in CAD. That way when we hatch a site pervious and impervious the numbers would automatically populate a catchmen...
over 2 years ago in Storm and Sewer Products / PondPack 1 Needs Review

Flowmaster Grate Interface

Provide a cleaner interface for grate inlet analysis for custom grate specs. I have struggled with using flowmaster for special grates we are using for airport applications. I have the opening area and perimeter but I cannot input custom variables...
over 2 years ago in Storm and Sewer Products / FlowMaster 0 Reviewed

Flowmaster Inlet Grates

it would be helpful to be able to analyze inlets that have slanted grates that are slanted in the direction of gutter flow. These grates are commonly used in DOT design as well as private applications. Please see attachment.
over 2 years ago in Storm and Sewer Products 0 Needs Review

2d module hot file

For 2d calculation, the option for hot start should be added, especially that this kind of calculations takes long time.
almost 3 years ago in Storm and Sewer Products / SewerGEMS 0 Reviewed

Hydraulic toolbox

incorporate the FHWA hydraulic toolbox into the product for quick calcs, channel lining, culvert outlet protection, etc... Could be an add on that can pull the data out of the model.
over 1 year ago in Storm and Sewer Products / StormCAD 0 Reviewed

Warning for Acute Angles Between Inlet and Outlet Pipes

Problem: The software does not warn users when the angle between the inlet and outlet pipes at a manhole is less than 90 degrees, which is a design flaw. Suggestion: Activate a warning when acute angles are detected between inlet and outlet pipes.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Reviewed

Automatic Manhole Numbering

Problem: Manhole numbering is done manually according to the layout of main lines and branches, which is time-consuming and error-prone. Suggestion: Add a feature for automatic numbering of manholes based on the network’s sequence.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Reviewed