StormCAD dynamic links to Civil 3D

For StormCAD it would be very helpful to also have a dynamic link between Civil 3D stormwater pipes and StormCAD pipes. We have to run two models essentially and there is a lot of translating data from one model into the other and time spend makin...
9 months ago in Storm and Sewer Products / StormCAD 0 Needs review

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Use a contour file to automatically set the elevation of new elements when I add them instead of having to use TRex repeatedly

I'm using WaterCAD and WaterGEMS for modeling and every time I add a new feature that is not on an already existing pipe, I need to set the elevation manually. For this I use TRex to set the elevation based on an ESRI contours shapefile from USGS....
5 months ago in Water Distribution Products / WaterCAD 0 Needs review

SewerGEMS: Adding minimum and average flow rates through a conduit

SewerGEMS software allows you to display the results of calculating the flow rate through a conduit (instantaneous and maximum). However, it is not possible to display the minimum and average values Suggestion: Add "Flow (Average)" and "Flow (Mini...
over 1 year ago in Storm and Sewer Products / SewerGEMS 1 Needs review

The 2D model does not recognize the assignment of LID. Implementation is suggested.

El modelo 2D no reconoce la asignación de LID. Se sugiere la implementación. Es importante simular inundaciones y verificar el comportamiento del alcantarillado al aplicar soluciones de drenaje sostenible.
5 months ago in Storm and Sewer Products / SewerGEMS 1 Needs review

element property interfacing upgrade

This feature should address pipes start/stop and not the manhole invert incase of a drop at the downstream manhole.
6 months ago in Storm and Sewer Products / SewerCAD 0 Needs review

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
6 months ago in Storm and Sewer Products / SewerCAD 0 Needs review

Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
6 months ago in Water Distribution Products / WaterGEMS 0 Needs review