WaterGems Quick Start Lessons

Missing step in quick start guide: In step 2, point 9 the lesson suggested that simply right-clicking in the drawing pane would let you add a reservoir. In reality, you needed to first click on the Pipe icon. After doing this, the right-click cont...
4 months ago in Water Distribution Products / WaterGEMS 0 Planned

Globally edit pipe material and associated properties

When globally editing pipe material in WaterCAD (using flextables -->pipe), the current option allows you to type in the name of the material, but the associated pipe properties are not updated. It would be convenient if you could globally edit...
7 months ago in Water Distribution Products / WaterCAD 0 Future consideration

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
over 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

Customer Meter Demand & Pressure support for Scada Elements

Most of our large customers are measured using smart meters which are present in our Scada System. Please add support for Scada Elements to connect to customer meters directly (demand & pressure).
about 2 years ago in Water Distribution Products / WaterGEMS 3 Future consideration

Bentley HAMMER batch compute option to run scenarios concurrently rather than consecutively

Hi Bentley Team, HAMMER currently runs batch computed scenarios sequentially. For complex models with multiple scenarios this often results in computations running overnight or even over several days to complete a batch of several scenarios. If po...
over 2 years ago in Water Distribution Products / HAMMER 3 Future consideration

Engineering Profile for WaterGEMS

Current profiles in WaterGEMS are too flat for clear visualization of network issues. Engineering-style profiles would provide a detailed view, showing pipe sizes, fittings, and key hydraulic data. This would help engineers better understand press...
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery controls bug

If I create controls for a VSP Battery element, close the controls dialog, then try to edit the controls by clicking the [...] in the VSP battery properties window, no controls will show up. The controls are visible in the full controls window. Se...
5 months ago in Water Distribution Products / WaterCAD 0 Planned

Resizeable color coding properties dialog

Sometimes you need to color code by a field that has long values or a lot of values. The color coding properties dialog lets you resize the columns in the table, but doesn't let you resize the window, making it difficult to work with.
5 months ago in Water Distribution Products / WaterCAD 0 Needs review

Put the laterals and taps adjacent to each other in the element symbology TOC

I usually need to turn laterals and taps on or off at the same time, so it would be helpful to have them next to each other to make it easier to do without scrolling.
5 months ago in Water Distribution Products / WaterCAD 0 Needs review

Element symbology improvement

When you have a bunch of annotations and color coding for each element type, it becomes hard to differentiate the sections. It would be nice if there was an easier way to distinguish the element types from the annotations/color coding. If the elem...
5 months ago in Water Distribution Products / WaterCAD 0 Needs review