Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 43

Bentley HAMMER batch compute option to run scenarios concurrently rather than consecutively

Hi Bentley Team, HAMMER currently runs batch computed scenarios sequentially. For complex models with multiple scenarios this often results in computations running overnight or even over several days to complete a batch of several scenarios. If po...
about 2 years ago in Water Distribution Products / HAMMER 3 Future consideration

Conduit Shape Enhancement (Circular Open Channel)

Create a shape where the semi-circle is at the bottom of the channel in order to model a circular open channel section.
about 2 years ago in Storm and Sewer Products / CivilStorm 1 Future consideration

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

Customer Meter Demand & Pressure support for Scada Elements

Most of our large customers are measured using smart meters which are present in our Scada System. Please add support for Scada Elements to connect to customer meters directly (demand & pressure).
over 1 year ago in Water Distribution Products / WaterGEMS 3 Future consideration

Network trace query to trace pressure zones

It would be very useful to have a query similar to "Find connected" that stops at pressure zone boundary elements. The "Pressure Zone" analysis tool kind of does this, but a query that can do this on the fly from a starting element would be really...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

Open on selection for controls table

Sometimes you need to look at the controls for several facilities at once (e.g., two different pump stations that serve the same zone), and don't want to open the full controls table. It would be convenient to have an option to "open on selection"...
10 months ago in Water Distribution Products / WaterCAD 0 Future consideration

HAMMER: Transient Results Viewer\Extended Node Data\Hydropneumatic Tank: the pressure or head engineering units indicated as absolute values on the Y axis. Without such mention a gauge value is assumed.

A new user looking for the first time at a pressure or head graph might be fooled by the fact that the Y axis does not mention that the units being graphed are in an absolute value. He or she might think hey I'm ok, minimum gauge value is 10 meter...
almost 2 years ago in Water Distribution Products / HAMMER 1 Future consideration

Add a toggle to disable moving elements in stand-alone applications.

It is far too easy to move elements in stand-alone WaterGEMS, such that I frequently move things by accident (thank you for easy undo). It would be nice to have the option to disable moving elements since we're 1:1 integrated with GIS and I rarely...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Future consideration

export all element types at once to shapefiles

export all element types at once to shape files
over 1 year ago in Storm and Sewer Products / CivilStorm 0 Future consideration

Create buttons to change Worksheet order in Project Explorer window of FlowMaster.

Create buttons to change Worksheet order in Project Explorer window of FlowMaster. This gives the user the opportunity to order Worksheets in a logical way as the Project evolves.
about 1 year ago in Storm and Sewer Products / FlowMaster 1 Future consideration