HAMMER: Transient Results Viewer\Extended Node Data\Hydropneumatic Tank: the pressure or head engineering units indicated as absolute values on the Y axis. Without such mention a gauge value is assumed.

A new user looking for the first time at a pressure or head graph might be fooled by the fact that the Y axis does not mention that the units being graphed are in an absolute value. He or she might think hey I'm ok, minimum gauge value is 10 meter...
about 2 years ago in Water Distribution Products / HAMMER 1 Planned

Warning for Acute Angles Between Inlet and Outlet Pipes

Problem: The software does not warn users when the angle between the inlet and outlet pipes at a manhole is less than 90 degrees, which is a design flaw. Suggestion: Activate a warning when acute angles are detected between inlet and outlet pipes.
7 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Automatic Manhole Numbering

Problem: Manhole numbering is done manually according to the layout of main lines and branches, which is time-consuming and error-prone. Suggestion: Add a feature for automatic numbering of manholes based on the network’s sequence.
7 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Pipe Sizes and Slopes Based on Street Widths

Problem: Pipe diameters and slopes in rural area codes depend on the width of the streets and are currently input manually. Suggestion: Enable automatic selection of pipe diameters and slopes based on the street width in accordance with applicable...
7 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Support for Preliminary Design Using Google Maps

Problem: In preliminary design stages, the absence of topographic surveys forces designers to rely on Google Maps for drawing site layouts manually and extracting elevations using separate tools. Suggestion: Integrate Google Maps as a background w...
7 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Reorganize Order of Scenarios

Applicable to all CivilStorm/StormCAD/PondPack/OpenRoads Drainage products. It would b nice to be able to reorganize the scenarios (the ones on the same hierarchy level). Currently, the scenarios are organized in the order that they are created. B...
7 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Make sharing Shared FlexTables easier

This idea is relevant to all drainage-related products, especially OpenRoads Drainage. Currently the way to share Shared FlexTables across laptops requries users to copy a FlexTables XML folder into a very specific folder on their Cdrive. It would...
over 2 years ago in Storm and Sewer Products / CivilStorm 1 Future consideration

SewerGEMS: Adding an option to automatically save after completing calculations

SewerGEMS stores the results in temporary files after the calculation is completed and the final design files with the results are created only after clicking "Save". It would be useful to have an option for the model to save itself after the calc...
over 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

SewerGEMS: Implementing tools for model skeletonization

The SewerGEMS development currently has no module, function or option to simplify the sewer network model. Such a tool is present implemented in the WaterGEMS software. It is clear that simplification on the sewer network may be more difficult to ...
over 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

SewerGEMS: Extension of data export from Hydraulic Reviewer Tool

SewerGEMS software, and more specifically the Hydraulic Reviewer Tool, allows you to display pipe flow statistics, among other things. There is a tool to export this data to the model, which is described in detail in the "Results Export" section o...
over 2 years ago in Storm and Sewer Products / SewerGEMS 1 Future consideration