Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Ideas

Showing 140 of 197

CREATING CUSTOMIZED USER DATA EXTENSION

Add some user defined output text output in user data extensions for Real(formula) option. For example: Let the Depth of structure > 2m, for this i want to show result " High Depth" otherwise "Correct depth" In existing methods, we can get only...
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Have parametric cells for nodes

Parametric cells for nodes will enable the software to increase the size of the node when required by capacity calculations. It can also change the node size when required to accommodate larger pipes. This will also reduce the size of the cell lib...
over 2 years ago in Storm and Sewer Products / CivilStorm 1 Needs review

Add the PondPack Pond Estimated Storage calculator to OpenFlows CivilStorm

Add the PondPack Pond Estimated Storage calculator to OpenFlows CivilStorm. There is no comparable analysis tool in CivilStorm.
over 2 years ago in Storm and Sewer Products / CivilStorm 1 Already exists

[Copy] Connect a channel directly to an On Grade Inlet

It would be great if ORD had the capability to connect a channel directly to an On Grade Inlet to be able to calculate spread and bypass at the inlet. Currently the workaround is to connect the channel to a Generic Outfall at the edge of the inlet...
10 months ago in Storm and Sewer Products 0 Needs review

Calculate the difference between the conduit invert stop and the downstream manhole invert level (Add a new field in conduit properties)

it will be useful for whom want to know if a weir is required to be added into the downstream manhole (in case the manhole has more then one weir)
over 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

Max Velocity constraint variable according to pipe diameter

In Portugal, as in several countries for where we work, maximum flow velocity in each pipe depends on its diameter. So that, as happens in SewerGEMS, velocity design constraint should be defined for each diameter, and should be a property of each ...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

StormCAD dynamic links to Civil 3D

For StormCAD it would be very helpful to also have a dynamic link between Civil 3D stormwater pipes and StormCAD pipes. We have to run two models essentially and there is a lot of translating data from one model into the other and time spend makin...
almost 2 years ago in Storm and Sewer Products / StormCAD 0 Needs review

PondPack Import Catchment Areas

The most helpful thing for how I use PondPack would be the ability to import catchment areas from CAD polyline work and maybe hatches in CAD. That way when we hatch a site pervious and impervious the numbers would automatically populate a catchmen...
almost 2 years ago in Storm and Sewer Products / PondPack 0 Needs review

Flowmaster Grate Interface

Provide a cleaner interface for grate inlet analysis for custom grate specs. I have struggled with using flowmaster for special grates we are using for airport applications. I have the opening area and perimeter but I cannot input custom variables...
almost 2 years ago in Storm and Sewer Products / FlowMaster 0 Needs review

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Needs review