Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

WaterGEMS

Showing 13

Improve Graph Default Interval Increments

Sometimes WaterGEMS seems to have the most peculiar default intervals on graphs on the y-axis. I regularly see intervals of 0.63, 1.25,12.5, and 62.50. All of these tend to obscure the values I actually care about. I would much rather see interval...
about 19 hours ago in Water Distribution Products / WaterGEMS 0 Needs review

Engineering Profile for WaterGEMS

Current profiles in WaterGEMS are too flat for clear visualization of network issues. Engineering-style profiles would provide a detailed view, showing pipe sizes, fittings, and key hydraulic data. This would help engineers better understand press...
9 days ago in Water Distribution Products / WaterGEMS 0 Needs review

Max Velocity constraint variable according to pipe diameter

In Portugal, as in several countries for where we work, maximum flow velocity in each pipe depends on its diameter. So that, as happens in SewerGEMS, velocity design constraint should be defined for each diameter, and should be a property of each ...
15 days ago in Water Distribution Products / WaterGEMS 0 Needs review

Options for changing the color of the line

Sometimes it is necessary to mark territory in the network when presenting simulation results to colleagues. Currently, the ability to draw is only assigned with black color and standard line thickness.
6 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Add direct access single click tool for selecting all upstream and all downstream pipes.

I suggest adding separate single click direct access tool or button (Water CAD/Water GEM) to selecting upstream and downstream pipes. It has the potential to save time and improve modeller's efficiency. This selection can be done through Navigator...
8 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
12 months ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
12 months ago in Water Distribution Products / WaterGEMS 0 Needs review

adding Model name and # of nodes/pipes to usage report

In order to have better visibility on the work done and distribute the cost charging among different projects, it would be nice to have the below additional into to the e365 open flows product usage: Number of actual model nodes/pipes Model File N...
6 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

PRV that can control pressure at a remote node

Some hydraulic modelling software allows users to specify a remote node which as the target for PRV pressure settings. For example a PRV at the entrance of a zone might modulate so that the pressure doesn't exceed 30m at the node in the zone with ...
7 months ago in Water Distribution Products / WaterGEMS 0 Needs review