SewerGEMS: Adding minimum and average flow rates through a conduit

SewerGEMS software allows you to display the results of calculating the flow rate through a conduit (instantaneous and maximum). However, it is not possible to display the minimum and average values Suggestion: Add "Flow (Average)" and "Flow (Mini...
almost 2 years ago in Storm and Sewer Products / SewerGEMS 1 Needs review

StormCAD dynamic links to Civil 3D

For StormCAD it would be very helpful to also have a dynamic link between Civil 3D stormwater pipes and StormCAD pipes. We have to run two models essentially and there is a lot of translating data from one model into the other and time spend makin...
about 1 year ago in Storm and Sewer Products / StormCAD 0 Needs review

PondPack Import Catchment Areas

The most helpful thing for how I use PondPack would be the ability to import catchment areas from CAD polyline work and maybe hatches in CAD. That way when we hatch a site pervious and impervious the numbers would automatically populate a catchmen...
about 1 year ago in Storm and Sewer Products / PondPack 0 Needs review

Flowmaster Grate Interface

Provide a cleaner interface for grate inlet analysis for custom grate specs. I have struggled with using flowmaster for special grates we are using for airport applications. I have the opening area and perimeter but I cannot input custom variables...
about 1 year ago in Storm and Sewer Products / FlowMaster 0 Needs review

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Maximum spread and depth results

Hello,In sewerGEMS, especially whem modelling dual-drainage system with gutters along the road, I'd like to request to get the max spread and depth results as a Property for gutters so it can be reported on in the FlexTable (without having to move...
about 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Flowmaster Inlet Grates

it would be helpful to be able to analyze inlets that have slanted grates that are slanted in the direction of gutter flow. These grates are commonly used in DOT design as well as private applications. Please see attachment.
about 1 year ago in Storm and Sewer Products 0 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Profile - Elevation outflow pipe

In the "profile," it is necessary to present the "elevations outflow" of the pipe being represented, not the elevation of the bottom of the manhole. In situations where the pipe reaches well above the bottom, it is necessary to switch variables, w...
7 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review