Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Storm and Sewer Products

Showing 77

Maximum spread and depth results

Hello,In sewerGEMS, especially whem modelling dual-drainage system with gutters along the road, I'd like to request to get the max spread and depth results as a Property for gutters so it can be reported on in the FlexTable (without having to move...
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Flowmaster Inlet Grates

it would be helpful to be able to analyze inlets that have slanted grates that are slanted in the direction of gutter flow. These grates are commonly used in DOT design as well as private applications. Please see attachment.
over 1 year ago in Storm and Sewer Products 0 Needs review

Have parametric cells for nodes

Parametric cells for nodes will enable the software to increase the size of the node when required by capacity calculations. It can also change the node size when required to accommodate larger pipes. This will also reduce the size of the cell lib...
about 2 years ago in Storm and Sewer Products / CivilStorm 1 Needs review

Profile - Elevation outflow pipe

In the "profile," it is necessary to present the "elevations outflow" of the pipe being represented, not the elevation of the bottom of the manhole. In situations where the pipe reaches well above the bottom, it is necessary to switch variables, w...
10 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

adding Model name and # of nodes/pipes to usage report

In order to have better visibility on the work done and distribute the cost charging among different projects, it would be nice to have the below additional into to the e365 open flows product usage: Number of actual model nodes/pipes Model File N...
11 months ago in Storm and Sewer Products / SewerGEMS 1 Needs review

Angle Readout for Node Angle Flex Tables for Stormwater Nodes to be in Degrees, Minutes Seconds. Not Degrees or Minutes or Seconds.

Setout Instruments do not read decimal degrees. It is incorrect to specify angles in just Minutes, or Seconds
about 2 years ago in Storm and Sewer Products / CivilStorm 0 Needs review

The 2D model does not recognize the assignment of LID. Implementation is suggested.

El modelo 2D no reconoce la asignación de LID. Se sugiere la implementación. Es importante simular inundaciones y verificar el comportamiento del alcantarillado al aplicar soluciones de drenaje sostenible.
about 1 year ago in Storm and Sewer Products / SewerGEMS 1 Needs review

element property interfacing upgrade

This feature should address pipes start/stop and not the manhole invert incase of a drop at the downstream manhole.
about 1 year ago in Storm and Sewer Products / SewerCAD 0 Needs review

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
about 1 year ago in Storm and Sewer Products / SewerCAD 0 Needs review

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review