Showing 181

Add a flex table and/or create a summary report (PDF) containing the kinematic flow variables for TR-55 or HEC-22 methods.

The required variables are user entered. None currently are retrieved from the model. Most variables are user defined. Slope and segment values could be populated from the model. We need a table or report for checking the calcs and for legal archi...
5 months ago in Storm and Sewer Products / StormCAD 0 Needs review

Options for changing the color of the line

Sometimes it is necessary to mark territory in the network when presenting simulation results to colleagues. Currently, the ability to draw is only assigned with black color and standard line thickness.
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

initial abstraction ratio

State agency requires initial abstraction ratio (Ia/s) to be 0.05 for RPv events. software assumes default value of 0.2, and the user can't change it. We need to have an option to adjust initial abstraction ratio for specific scenarios of SCS unit...
5 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

[Copy] External Flow Utility Properties for Manholes

Catch basins have the following flow types that can be added: additional subsurface flow (cfs), known flow (cfs), additional carryover flow (cfs), external CA (acres), and external Tc (min). Manholes only have the option of known flow. Known flows...
8 months ago in Storm and Sewer Products 1 Needs review

Selecting Upstream Catchments

We asking for a tool in SewerGEMS for directly select connected or upstream catchments to the element of for a specified outfall.
over 2 years ago in Storm and Sewer Products / SewerGEMS 2 Planned

Time of concentration reported in flextable format

It would be nice to be able to enter and edit time of concentration information in a flextable format. Currently a separate dialog box must be opened for each catchment area to input Tc data for Tc computation. To review the inputs of the Tc compu...
8 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Customer Meter Associated Element - Physical Alternative as Default, not Demand Alternative

Currently it is extremely tedious to change the Associated Element of a Customer Meter Model Element. An unfortunate design choice during Customer Meter implementation into WaterCAD was that within the WaterCAD Schema this Attribute was assigned t...
over 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

Add Capability to Input Custom Grate Area and Perimeter and Report Output Grate Area and Perimeter

Even though grate input parameters such as grate length, grate width, and clogging factor already exist, the resulting grate area and perimeter used in both weir and orifice calculations are not reported as calculation outputs. The end user cannot...
3 months ago in Storm and Sewer Products / StormCAD 0 Needs review

VSP Battery controls bug

If I create controls for a VSP Battery element, close the controls dialog, then try to edit the controls by clicking the [...] in the VSP battery properties window, no controls will show up. The controls are visible in the full controls window. Se...
3 months ago in Water Distribution Products / WaterCAD 0 Planned

Resizeable color coding properties dialog

Sometimes you need to color code by a field that has long values or a lot of values. The color coding properties dialog lets you resize the columns in the table, but doesn't let you resize the window, making it difficult to work with.