Globally edit pipe material and associated properties

When globally editing pipe material in WaterCAD (using flextables -->pipe), the current option allows you to type in the name of the material, but the associated pipe properties are not updated. It would be convenient if you could globally edit...
5 months ago in Water Distribution Products / WaterCAD 0 Future consideration

Add a flex table and/or create a summary report (PDF) containing the kinematic flow variables for TR-55 or HEC-22 methods.

The required variables are user entered. None currently are retrieved from the model. Most variables are user defined. Slope and segment values could be populated from the model. We need a table or report for checking the calcs and for legal archi...
5 months ago in Storm and Sewer Products / StormCAD 0 Needs review

initial abstraction ratio

State agency requires initial abstraction ratio (Ia/s) to be 0.05 for RPv events. software assumes default value of 0.2, and the user can't change it. We need to have an option to adjust initial abstraction ratio for specific scenarios of SCS unit...
5 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

[Copy] External Flow Utility Properties for Manholes

Catch basins have the following flow types that can be added: additional subsurface flow (cfs), known flow (cfs), additional carryover flow (cfs), external CA (acres), and external Tc (min). Manholes only have the option of known flow. Known flows...
8 months ago in Storm and Sewer Products 1 Needs review

Selecting Upstream Catchments

We asking for a tool in SewerGEMS for directly select connected or upstream catchments to the element of for a specified outfall.
over 2 years ago in Storm and Sewer Products / SewerGEMS 2 Planned

Customer Meter Associated Element - Physical Alternative as Default, not Demand Alternative

Currently it is extremely tedious to change the Associated Element of a Customer Meter Model Element. An unfortunate design choice during Customer Meter implementation into WaterCAD was that within the WaterCAD Schema this Attribute was assigned t...
over 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

Time of concentration reported in flextable format

It would be nice to be able to enter and edit time of concentration information in a flextable format. Currently a separate dialog box must be opened for each catchment area to input Tc data for Tc computation. To review the inputs of the Tc compu...
9 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Snapping Tools in SewerGEMS Standalone

It is very important to provide a Snapping Tools to the SewerGEMS Standalone for better digitizing and allocating element on the other elements, for example Tap element to the pipe.
over 2 years ago in Storm and Sewer Products / SewerGEMS 3 Needs review

Add Capability to Input Custom Grate Area and Perimeter and Report Output Grate Area and Perimeter

Even though grate input parameters such as grate length, grate width, and clogging factor already exist, the resulting grate area and perimeter used in both weir and orifice calculations are not reported as calculation outputs. The end user cannot...
3 months ago in Storm and Sewer Products / StormCAD 0 Needs review

NRCS/SCS Peak Discharge