VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

adding Model name and # of nodes/pipes to usage report

In order to have better visibility on the work done and distribute the cost charging among different projects, it would be nice to have the below additional into to the e365 open flows product usage: Number of actual model nodes/pipes Model File N...
8 months ago in Water Distribution Products / WaterGEMS 0 Needs review

PRV that can control pressure at a remote node

Some hydraulic modelling software allows users to specify a remote node which as the target for PRV pressure settings. For example a PRV at the entrance of a zone might modulate so that the pressure doesn't exceed 30m at the node in the zone with ...
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Saved hydrant flow curves should include chart formatting

When saving a hydrant flow curve in WaterGEMS, it doesn't save the custom formatting of the hydrant curve graph. If I create a hydrant curve and set the y axis to show intervals of 5 or 10 psi, when I save the curve and reopen it, the curve revert...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...