Add New Features through ModelBuilder to All Topologies

I know you can configure your [Active] topology data sets to cascade, but sometimes we inherit models that are not set up like this. When you do a bulk import, you have to then go and activate every feature set for every [Active] topology. Add a c...
3 months ago in Water Distribution Products / WaterGEMS 0 Future consideration

Post Calculation Processor Enhancements

Currently there is only one post calculation. It's a pain to keep reconfiguring the calculator. This could be a data store like most other things in GEMS where you can make a new one, edit them, pick which ones are active or which to run after a s...
3 months ago in Water Distribution Products / WaterGEMS 0 Future consideration

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

Fix FCV calculation routine and/or add calculation option

Background info (including Jesse Dringoli's response) can be found here. The Flow Control Valve (FCV) calculations in WaterGEMS currently allows the calculated Cv value to exceed the fully open Cv value. The link to the Forum post above includes m...
4 months ago in Water Distribution Products / WaterGEMS 1 Needs review

Customer Meter Demand & Pressure support for Scada Elements

Most of our large customers are measured using smart meters which are present in our Scada System. Please add support for Scada Elements to connect to customer meters directly (demand & pressure).
over 1 year ago in Water Distribution Products / WaterGEMS 3 Future consideration

Max Velocity constraint variable according to pipe diameter

In Portugal, as in several countries for where we work, maximum flow velocity in each pipe depends on its diameter. So that, as happens in SewerGEMS, velocity design constraint should be defined for each diameter, and should be a property of each ...
5 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Add a toggle to disable moving elements in stand-alone applications.

It is far too easy to move elements in stand-alone WaterGEMS, such that I frequently move things by accident (thank you for easy undo). It would be nice to have the option to disable moving elements since we're 1:1 integrated with GIS and I rarely...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Future consideration

Add direct access single click tool for selecting all upstream and all downstream pipes.

I suggest adding separate single click direct access tool or button (Water CAD/Water GEM) to selecting upstream and downstream pipes. It has the potential to save time and improve modeller's efficiency. This selection can be done through Navigator...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review