create several computational meshes at once

SewerGEMS with 2D currently has computational meshes applied for one polygon, It is required to create several computational meshes at once for many polygons in different locations and would to create a mesh for all of them at once
3 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Profile - Elevation outflow pipe

In the "profile," it is necessary to present the "elevations outflow" of the pipe being represented, not the elevation of the bottom of the manhole. In situations where the pipe reaches well above the bottom, it is necessary to switch variables, w...
19 days ago in Storm and Sewer Products / SewerGEMS 0 Needs review

adding Model name and # of nodes/pipes to usage report

In order to have better visibility on the work done and distribute the cost charging among different projects, it would be nice to have the below additional into to the e365 open flows product usage: Number of actual model nodes/pipes Model File N...
28 days ago in Storm and Sewer Products / SewerGEMS 1 Needs review

Tools that assist in automating calibration

A tool that streamlines the iterative process of calibrating a model. Allows the user to input upper and lower values for parameters such as %Imperviousness, Dstorage, RTK, etc. The software would then iterate or use a genetic algorithm to assist ...
6 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Snapping Tools in SewerGEMS Standalone

It is very important to provide a Snapping Tools to the SewerGEMS Standalone for better digitizing and allocating element on the other elements, for example Tap element to the pipe.
over 1 year ago in Storm and Sewer Products / SewerGEMS 3 Needs review

The 2D model does not recognize the assignment of LID. Implementation is suggested.

El modelo 2D no reconoce la asignación de LID. Se sugiere la implementación. Es importante simular inundaciones y verificar el comportamiento del alcantarillado al aplicar soluciones de drenaje sostenible.
3 months ago in Storm and Sewer Products / SewerGEMS 1 Needs review

StormCAD dynamic links to Civil 3D

For StormCAD it would be very helpful to also have a dynamic link between Civil 3D stormwater pipes and StormCAD pipes. We have to run two models essentially and there is a lot of translating data from one model into the other and time spend makin...
7 months ago in Storm and Sewer Products / StormCAD 0 Needs review

element property interfacing upgrade

This feature should address pipes start/stop and not the manhole invert incase of a drop at the downstream manhole.
3 months ago in Storm and Sewer Products / SewerCAD 0 Needs review

SewerGEMS: Grey out unnecessary tools and options in ribbons

SewerGEMS software dynamically hides attributes in the object properties window that are not used at given settings in calculations. However, this approach is not applied to the options and tools visible in the ribbons. Suggestion: Tools and optio...
over 1 year ago in Storm and Sewer Products / SewerGEMS 1 Needs review

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
4 months ago in Storm and Sewer Products / SewerCAD 0 Needs review