Reorganize Order of Scenarios

Applicable to all CivilStorm/StormCAD/PondPack/OpenRoads Drainage products. It would b nice to be able to reorganize the scenarios (the ones on the same hierarchy level). Currently, the scenarios are organized in the order that they are created. B...
about 7 hours ago in Storm and Sewer Products / CivilStorm 0 Needs review

initial abstraction ratio

State agency requires initial abstraction ratio (Ia/s) to be 0.05 for RPv events. software assumes default value of 0.2, and the user can't change it. We need to have an option to adjust initial abstraction ratio for specific scenarios of SCS unit...
5 days ago in Storm and Sewer Products / CivilStorm 0 Needs review

Time of concentration reported in flextable format

It would be nice to be able to enter and edit time of concentration information in a flextable format. Currently a separate dialog box must be opened for each catchment area to input Tc data for Tc computation. To review the inputs of the Tc compu...
3 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Calculate catchment area runoff without an outflow node

Applicable to CivilStorm, StormCADD, and PondPack. Sometimes we only want to calculate the runoff generated by a catchment area. However, catchment areas do not calculate runoff unless a outflow node is specified. White it's not terribly difficult...
4 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Make it easier to integrate with projectwise

Currently, to allow CivilStorm (and I'm assuming StormCAD/PondPak) to integrate with ProjectWise, we have to edit an XML file following this guidance: https://bentleysystems.service-now.com/community?id=kb_article_view&sysparm_article=KB005824...
4 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Perform only necessary computations

Applicable to CivilStorm, StormCAD, and probably PondPack. Sometimes we only use the software to perform certain computations. For example, we are wanting to analyze the storm sewer. The drainage areas would be connected to catchbasin elements. Ho...
4 months ago in Storm and Sewer Products / CivilStorm 1 Needs review

Have parametric cells for nodes

Parametric cells for nodes will enable the software to increase the size of the node when required by capacity calculations. It can also change the node size when required to accommodate larger pipes. This will also reduce the size of the cell lib...
almost 2 years ago in Storm and Sewer Products / CivilStorm 1 Needs review

Add back-drop height property

Please add a property to all the chambers including both catchbasins and manhole which specify the back drop height (multiple values if we have multiple incoming pipes)
over 1 year ago in Storm and Sewer Products / CivilStorm 1 Needs review

Angle Readout for Node Angle Flex Tables for Stormwater Nodes to be in Degrees, Minutes Seconds. Not Degrees or Minutes or Seconds.

Setout Instruments do not read decimal degrees. It is incorrect to specify angles in just Minutes, or Seconds
almost 2 years ago in Storm and Sewer Products / CivilStorm 0 Needs review

This is a test