Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 161

Option to account for surcharge for enclosed storage

For enclosed storages that are undersized and are required to analyze the effects of surcharge, it would be usedful to have a field when created a pond, where you can seleect if the "pond" is enclosed and if you would like to account for surcharge...
3 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Bentley HAMMER batch compute option to run scenarios concurrently rather than consecutively

Hi Bentley Team, HAMMER currently runs batch computed scenarios sequentially. For complex models with multiple scenarios this often results in computations running overnight or even over several days to complete a batch of several scenarios. If po...
almost 2 years ago in Water Distribution Products / HAMMER 3 Future consideration

[Copy] It would be beneficial to allow drainage designers to use graphical elements in combination with terrains to define time of concentration components

Currently, in order to determine one of the components of the Time of Concentration (Tc), ORD DU users have to jump completely out of the 'Catchment Properties' interface to determine the length and slope of the Tc element (since once you are in t...
3 months ago in Storm and Sewer Products 0 Needs review

[Copy] ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
3 months ago in Storm and Sewer Products 0 Needs review

[Copy] Openroads Drainage - HGL versus Headwater Analysis for Headwalls Inletting into a Storm Sewer System

Many times, a stream needs to be drained into a storm sewer system via a headwall. When this occurs, two analysis should be considered: The headwater at the headwall (the mechanics of the water getting into the pipe at the headwall). Generally K...
3 months ago in Storm and Sewer Products 0 Needs review

[Copy] Add ability to set default Engineering Libraries for all users

As it stands, I can make a new Engineering Library on a network drive to share with other users, but if I wanted to make that library the "default", I can't without having to make the change for each individual user.
3 months ago in Storm and Sewer Products 0 Needs review

[Copy] Calculation Summary ("Report") Improvement Suggestions

The calculation executive summary and calculation detailed summary would be improved by adding a time stamp near the date and file name at the bottom of the reports' pages. It would be helpful to be able to add a note to the reports describing tha...
3 months ago in Storm and Sewer Products 0 Needs review

Conduit Shape Enhancement (Circular Open Channel)

Create a shape where the semi-circle is at the bottom of the channel in order to model a circular open channel section.
almost 2 years ago in Storm and Sewer Products / CivilStorm 1 Future consideration

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Future consideration

Open on selection for controls table

Sometimes you need to look at the controls for several facilities at once (e.g., two different pump stations that serve the same zone), and don't want to open the full controls table. It would be convenient to have an option to "open on selection"...
7 months ago in Water Distribution Products / WaterCAD 0 Future consideration