Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Storm and Sewer Products

Showing 87

Calculate the difference between the conduit invert stop and the downstream manhole invert level (Add a new field in conduit properties)

it will be useful for whom want to know if a weir is required to be added into the downstream manhole (in case the manhole has more then one weir)
almost 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

Make sharing Shared FlexTables easier

This idea is relevant to all drainage-related products, especially OpenRoads Drainage. Currently the way to share Shared FlexTables across laptops requries users to copy a FlexTables XML folder into a very specific folder on their Cdrive. It would...
almost 2 years ago in Storm and Sewer Products / CivilStorm 0 Future consideration

The 2D model does not recognize the assignment of LID. Implementation is suggested.

El modelo 2D no reconoce la asignación de LID. Se sugiere la implementación. Es importante simular inundaciones y verificar el comportamiento del alcantarillado al aplicar soluciones de drenaje sostenible.
10 months ago in Storm and Sewer Products / SewerGEMS 1 Needs review

element property interfacing upgrade

This feature should address pipes start/stop and not the manhole invert incase of a drop at the downstream manhole.
10 months ago in Storm and Sewer Products / SewerCAD 0 Needs review

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
10 months ago in Storm and Sewer Products / SewerCAD 0 Needs review

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.
about 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

SCS dimensionless curves for different durations

I advise to include the possibility for SCS dimensionless curves for 6 and 12 hours events instead of only 24 hours as per current OpenFlows products.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

2d module hot file

For 2d calculation, the option for hot start should be added, especially that this kind of calculations takes long time.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

Grid regeneration

The message prompting before every simulation computing is ambiguous - is it necessary to regenerate grid each time I want to compute model? Probably not if the grid wasn't changed.
almost 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Docking Grid Browser

It would be nice if the Grid browser could be docked on the side of the window.
almost 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review