Customer Meter Associated Element - Physical Alternative as Default, not Demand Alternative

Currently it is extremely tedious to change the Associated Element of a Customer Meter Model Element. An unfortunate design choice during Customer Meter implementation into WaterCAD was that within the WaterCAD Schema this Attribute was assigned t...
over 1 year ago in Water Distribution Products / WaterCAD 0 Future consideration

web-based model viewer

In our sector of the company just me had the software watergems, so it would be awesome if we had a web-based model viewer just to share the results of the models, like pressure zones or headlosses. It would be an huge step for us, we also could u...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

REGARDING WATER LEVEL VARIATION IN HYDRONEUMTIC TANK

SIR I HAVE SEEN THAT TRACKING OF WATER LEVEL OSCILLATION HAS NOT BEEN INCORPORATED IN HAMMER. INSTEAD GAS VOLUME VARIATION IS AVAILABLE. BUT IF OUR EXPERTS CAN IMPLEMENT THE WATER LEVEL VARIATION, IT IS SO HELPFUL.
3 months ago in Water Distribution Products / HAMMER 1 Already exists

turbine load acceptance followed by load rejection

sir the above case is so important in case of surge protection of tail race tunnel and head race tunnel. Also, now a days most of the hydropower plants, the surge tank has been replaced with SURGE GALLERY (IT IS JUST LIKE LONG PIPE OF HAVING DIFFR...
3 months ago in Water Distribution Products / HAMMER 0 Needs review

Graph of mass (real) air flow through an air valve

It would be better if the detailed airflow graph would show the "mass air flow rate" and thus the user can confirm whether real air volume was expelled from the air valve to the atmosphere or not. The current situation in which we watch "momentary...
4 months ago in Water Distribution Products / HAMMER 0 Needs review

When a surge relief valve dumps to a reservoir, can an external pressure input option be added to the software?

When a surge relief valve dumps to a reservoir, can an external pressure input option be added to the software? Other softwares for transient analysis have this input.
4 months ago in Water Distribution Products / HAMMER 1 Needs review

Bentley HAMMER batch compute option to run scenarios concurrently rather than consecutively

Hi Bentley Team, HAMMER currently runs batch computed scenarios sequentially. For complex models with multiple scenarios this often results in computations running overnight or even over several days to complete a batch of several scenarios. If po...
about 2 years ago in Water Distribution Products / HAMMER 3 Future consideration

Fix FCV calculation routine and/or add calculation option

Background info (including Jesse Dringoli's response) can be found here. The Flow Control Valve (FCV) calculations in WaterGEMS currently allows the calculated Cv value to exceed the fully open Cv value. The link to the Forum post above includes m...
4 months ago in Water Distribution Products / WaterGEMS 1 Needs review

Create Option to Allow Split Pipes to Get Assigned Next AutoID

Currently, if a pipe is split, say the pipe is P-10000, the new segments are P-10000(1) and P-10000(2). This gets really messy when a pipe is split multiple times. Add an option under Tools / Options to assign the split pipe label to the "Next" pi...
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

Extended node data (Report period) for check valves

A check valve is a fundamental device used in water systems. Having a detailed graph of its closing status, upstream vs. downstream pressure and other parameters will be super useful!. Thank you Tal