Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Storm and Sewer Products

Showing 95

Add Capability to Input Custom Grate Area and Perimeter and Report Output Grate Area and Perimeter

Even though grate input parameters such as grate length, grate width, and clogging factor already exist, the resulting grate area and perimeter used in both weir and orifice calculations are not reported as calculation outputs. The end user cannot...
3 months ago in Storm and Sewer Products / StormCAD 0 Needs review

Snapping Tools in SewerGEMS Standalone

It is very important to provide a Snapping Tools to the SewerGEMS Standalone for better digitizing and allocating element on the other elements, for example Tap element to the pipe.
over 2 years ago in Storm and Sewer Products / SewerGEMS 3 Needs review

NRCS/SCS Peak Discharge

Currently I use ORD and have to use Civilstorm license to run SCS hydrology. I don't really need the full hydrograph for all projects. It would be to have get peak discharge using the stormCAD license inside ORD.
6 months ago in Storm and Sewer Products / StormCAD 0 Needs review

Make it easier to integrate with projectwise

Currently, to allow CivilStorm (and I'm assuming StormCAD/PondPak) to integrate with ProjectWise, we have to edit an XML file following this guidance: https://bentleysystems.service-now.com/community?id=kb_article_view&sysparm_article=KB005824...
9 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Tools that assist in automating calibration

A tool that streamlines the iterative process of calibrating a model. Allows the user to input upper and lower values for parameters such as %Imperviousness, Dstorage, RTK, etc. The software would then iterate or use a genetic algorithm to assist ...
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

[Copy] Allow the road slope to exceed the gutter cross slope

My state agency commonly uses gutters with a 4% cross slope. The maximum superelevation rate is 7%. The gutter slope stays at 4% in this situation. Spread does not compute in this scenario because "A depressed gutter must have a Gutter Cross Slope...
8 months ago in Storm and Sewer Products 0 Needs review

Conduit Shape Enhancement (Circular Open Channel)

Create a shape where the semi-circle is at the bottom of the channel in order to model a circular open channel section.
over 2 years ago in Storm and Sewer Products / CivilStorm 1 Future consideration

Hydraulic toolbox

incorporate the FHWA hydraulic toolbox into the product for quick calcs, channel lining, culvert outlet protection, etc... Could be an add on that can pull the data out of the model.
4 months ago in Storm and Sewer Products / StormCAD 0 Needs review

Perform only necessary computations

Applicable to CivilStorm, StormCAD, and probably PondPack. Sometimes we only use the software to perform certain computations. For example, we are wanting to analyze the storm sewer. The drainage areas would be connected to catchbasin elements. Ho...
9 months ago in Storm and Sewer Products / CivilStorm 2 Needs review

Warning for Acute Angles Between Inlet and Outlet Pipes

Problem: The software does not warn users when the angle between the inlet and outlet pipes at a manhole is less than 90 degrees, which is a design flaw. Suggestion: Activate a warning when acute angles are detected between inlet and outlet pipes.
5 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review