Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Storm and Sewer Products

Showing 92

Automatic Manhole Numbering

Problem: Manhole numbering is done manually according to the layout of main lines and branches, which is time-consuming and error-prone. Suggestion: Add a feature for automatic numbering of manholes based on the network’s sequence.
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Pipe Sizes and Slopes Based on Street Widths

Problem: Pipe diameters and slopes in rural area codes depend on the width of the streets and are currently input manually. Suggestion: Enable automatic selection of pipe diameters and slopes based on the street width in accordance with applicable...
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Support for Preliminary Design Using Google Maps

Problem: In preliminary design stages, the absence of topographic surveys forces designers to rely on Google Maps for drawing site layouts manually and extracting elevations using separate tools. Suggestion: Integrate Google Maps as a background w...
2 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Make it easier to integrate with projectwise

Currently, to allow CivilStorm (and I'm assuming StormCAD/PondPak) to integrate with ProjectWise, we have to edit an XML file following this guidance: https://bentleysystems.service-now.com/community?id=kb_article_view&sysparm_article=KB005824...
7 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

Reorganize Order of Scenarios

Applicable to all CivilStorm/StormCAD/PondPack/OpenRoads Drainage products. It would b nice to be able to reorganize the scenarios (the ones on the same hierarchy level). Currently, the scenarios are organized in the order that they are created. B...
2 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

initial abstraction ratio

State agency requires initial abstraction ratio (Ia/s) to be 0.05 for RPv events. software assumes default value of 0.2, and the user can't change it. We need to have an option to adjust initial abstraction ratio for specific scenarios of SCS unit...
3 months ago in Storm and Sewer Products / CivilStorm 0 Needs review

[Copy] Allow the road slope to exceed the gutter cross slope

My state agency commonly uses gutters with a 4% cross slope. The maximum superelevation rate is 7%. The gutter slope stays at 4% in this situation. Spread does not compute in this scenario because "A depressed gutter must have a Gutter Cross Slope...
5 months ago in Storm and Sewer Products 0 Needs review

Selecting Upstream Catchments

We asking for a tool in SewerGEMS for directly select connected or upstream catchments to the element of for a specified outfall.
about 2 years ago in Storm and Sewer Products / SewerGEMS 2 Planned

Snapping Tools in SewerGEMS Standalone

It is very important to provide a Snapping Tools to the SewerGEMS Standalone for better digitizing and allocating element on the other elements, for example Tap element to the pipe.
about 2 years ago in Storm and Sewer Products / SewerGEMS 3 Needs review

Asociar property connection con su conduit.

En la actualidad sewergemes, permite hacer informes o reportes del lateral asociado a property connection y Tap ; y Tap asociado a conduit. En América latina, generalmente, la caja registro de desagüe ( property connection) esta asociada a un nume...
3 months ago in Storm and Sewer Products / SewerGEMS 0 Needs review