Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 122

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
over 1 year ago in Water Distribution Products / HAMMER 0 Needs review

Grid regeneration

The message prompting before every simulation computing is ambiguous - is it necessary to regenerate grid each time I want to compute model? Probably not if the grid wasn't changed.
about 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Docking Grid Browser

It would be nice if the Grid browser could be docked on the side of the window.
about 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
over 1 year ago in Water Distribution Products / WaterCAD 0 Needs review

Critical Referenced Model Elements: Soft or Hard Deletion Lockout

Some element deletion processes will create invalid, difficult to undo and difficult for some users to diagnose issues when the element is a critical reference element to a separate elements. Examples include: Downstream pipes of Directional Eleme...
over 1 year ago in Water Distribution Products / WaterCAD 0 Needs review

add storm input formatting for atlas 14

would be nice to add the duration depth frequency data as presented in atlas 14
over 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

SCS dimensionless curves for different durations

I advise to include the possibility for SCS dimensionless curves for 6 and 12 hours events instead of only 24 hours as per current OpenFlows products.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Allow reduction of MSX constituent concentration via [SOURCES]

No idea if this can actually be done because it's not currently a feature within MSX however it was suggested I add it here so here it is. Basically MSX only allows for adding constituents through the [SOURCES] controls, but it doesn't provide any...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Needs review

Decimal places for labels

Ability to specify decimal places when labeling an element with a number field (e.g., pipe diameter). This should not be linked to the decimal places seen elsewhere in flex table or the properties window.
about 2 years ago in Water Distribution Products / WaterCAD 0 Needs review

Statistics in results tables

The ability to calculate statistics in results tables (right-click, statistics) would be valuable. This feature already exists for FlexTables.
about 2 years ago in Water Distribution Products / WaterCAD 2 Needs review