Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Maximum spread and depth results

Hello,In sewerGEMS, especially whem modelling dual-drainage system with gutters along the road, I'd like to request to get the max spread and depth results as a Property for gutters so it can be reported on in the FlexTable (without having to move...
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Flowmaster Inlet Grates

it would be helpful to be able to analyze inlets that have slanted grates that are slanted in the direction of gutter flow. These grates are commonly used in DOT design as well as private applications. Please see attachment.
over 1 year ago in Storm and Sewer Products 0 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

hydrant as target element type in properties of SCADA element

Please make possible to assign SCADA signal with hydrant - for example for pressure. We are making very often measurements on hydrants and now if I would like to assign pressure records to hydrant I have to change hydrant to junction first. After ...
almost 2 years ago in Water Distribution Products / WaterGEMS 0 Future consideration

add Grate Width in utility Property

add Grate Width in Utility Property. (See Attachment)
about 2 years ago in Storm and Sewer Products / StormCAD 0 Future consideration

Complex Spread Section

Need the function same as Geopak where the user be able to input/use multiple shoulder and road section. (See attachment)
about 2 years ago in Storm and Sewer Products / StormCAD 0 Future consideration

Profile - Elevation outflow pipe

In the "profile," it is necessary to present the "elevations outflow" of the pipe being represented, not the elevation of the bottom of the manhole. In situations where the pipe reaches well above the bottom, it is necessary to switch variables, w...
about 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

adding Model name and # of nodes/pipes to usage report

In order to have better visibility on the work done and distribute the cost charging among different projects, it would be nice to have the below additional into to the e365 open flows product usage: Number of actual model nodes/pipes Model File N...
about 1 year ago in Storm and Sewer Products / SewerGEMS 1 Needs review