PRV that can control pressure at a remote node

Some hydraulic modelling software allows users to specify a remote node which as the target for PRV pressure settings. For example a PRV at the entrance of a zone might modulate so that the pressure doesn't exceed 30m at the node in the zone with ...
9 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Show bends in color on selected link when in Layout Mode

The bends are not distinct enough to reliably click on them to adjust them. The bends are not very visible and that makes it a hit or miss proposition as to whether I click on a bend or on a line. It is pretty aggravating to try to click on a bend...
10 months ago in Water Distribution Products / WaterGEMS 1 Planned

Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Saved hydrant flow curves should include chart formatting

When saving a hydrant flow curve in WaterGEMS, it doesn't save the custom formatting of the hydrant curve graph. If I create a hydrant curve and set the y axis to show intervals of 5 or 10 psi, when I save the curve and reopen it, the curve revert...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Access to fields of different objects in one tabular table

In many cases, it is required to access a specific field of a pipe in node tables or vice versa
almost 2 years ago in Water Distribution Products / WaterGEMS 5 Future consideration

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

hydrant as target element type in properties of SCADA element

Please make possible to assign SCADA signal with hydrant - for example for pressure. We are making very often measurements on hydrants and now if I would like to assign pressure records to hydrant I have to change hydrant to junction first. After ...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Future consideration

Add the ability to create a drop-down menu (predefined) User Data Extension field

This would work the same as the current boolean UDE field, but it would have options that can be predefined when creating the UDE field, this would be especially helpful since our custom control input variables are defined using UDE fields (it req...