Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

WaterGEMS

Showing 25

Saved hydrant flow curves should include chart formatting

When saving a hydrant flow curve in WaterGEMS, it doesn't save the custom formatting of the hydrant curve graph. If I create a hydrant curve and set the y axis to show intervals of 5 or 10 psi, when I save the curve and reopen it, the curve revert...
11 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Access to fields of different objects in one tabular table

In many cases, it is required to access a specific field of a pipe in node tables or vice versa
almost 2 years ago in Water Distribution Products / WaterGEMS 5 Future consideration

Cavitation Risk graphs for PRVs

Well, the idea it's to be able to generate a cavitation graph for PRVs. I usually use a specific website to design and find the right diameter for PRVs (bermad-sizing.com), it turns out that the input parameters on the website are pretty basic, li...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

hydrant as target element type in properties of SCADA element

Please make possible to assign SCADA signal with hydrant - for example for pressure. We are making very often measurements on hydrants and now if I would like to assign pressure records to hydrant I have to change hydrant to junction first. After ...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Future consideration

Add the ability to create a drop-down menu (predefined) User Data Extension field

This would work the same as the current boolean UDE field, but it would have options that can be predefined when creating the UDE field, this would be especially helpful since our custom control input variables are defined using UDE fields (it req...
almost 2 years ago in Water Distribution Products / WaterGEMS 2 Already exists