Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

WaterGEMS

Showing 25

Customer Meter Demand & Pressure support for Scada Elements

Most of our large customers are measured using smart meters which are present in our Scada System. Please add support for Scada Elements to connect to customer meters directly (demand & pressure).
over 1 year ago in Water Distribution Products / WaterGEMS 2 Future consideration

Add direct access single click tool for selecting all upstream and all downstream pipes.

I suggest adding separate single click direct access tool or button (Water CAD/Water GEM) to selecting upstream and downstream pipes. It has the potential to save time and improve modeller's efficiency. This selection can be done through Navigator...
10 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Add a toggle to disable moving elements in stand-alone applications.

It is far too easy to move elements in stand-alone WaterGEMS, such that I frequently move things by accident (thank you for easy undo). It would be nice to have the option to disable moving elements since we're 1:1 integrated with GIS and I rarely...
over 1 year ago in Water Distribution Products / WaterGEMS 0 Future consideration

Possibility to set pressure settings by SCADA element in SCADA Connect simulator

Please add possibility to override pressure settings in pumps and VPS battery pumps by SCADA data in SCADA Connect Simulator
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

VSP Battery as a target element for SCADA element

Please add possibility to set target element of SCADA element for VSP Battery pumps. It could be useful not only for viewing data, but it could be useful for the SCADA Connect simulations if you add possiblity to overriding pressure settings by SC...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

Criticality Results Demand Shortfall for individual Customer Elements and Demand Nodes

In summary, add a separate Individual Element Demand Shortfall (%) result to the Affected Customer Elements and Affected Nodes Criticality Results Tab. Include all Customer Elements and Affected Nodes that are below an Individual Element Demand Sh...
about 1 year ago in Water Distribution Products / WaterGEMS 0 Needs review

adding Model name and # of nodes/pipes to usage report

In order to have better visibility on the work done and distribute the cost charging among different projects, it would be nice to have the below additional into to the e365 open flows product usage: Number of actual model nodes/pipes Model File N...
8 months ago in Water Distribution Products / WaterGEMS 0 Needs review

PRV that can control pressure at a remote node

Some hydraulic modelling software allows users to specify a remote node which as the target for PRV pressure settings. For example a PRV at the entrance of a zone might modulate so that the pressure doesn't exceed 30m at the node in the zone with ...
8 months ago in Water Distribution Products / WaterGEMS 0 Needs review

Show bends in color on selected link when in Layout Mode

The bends are not distinct enough to reliably click on them to adjust them. The bends are not very visible and that makes it a hit or miss proposition as to whether I click on a bend or on a line. It is pretty aggravating to try to click on a bend...
10 months ago in Water Distribution Products / WaterGEMS 1 Planned

Enable input of TCV Control Opening Ratio Setting Type Actions

Enable the user to use the TCV Valve Characteristic Curves in Controls so that butterfly valves, globe valves etc. used as actuated flow control valves for level control in Tanks can be more easily modelled, and cut down on instances of users usin...
10 months ago in Water Distribution Products / WaterGEMS 0 Needs review