Option to lock down and only able to save files in ProjectWise

Lock down to only have the ability to save files in ProjectWise will give organizations better control of files being properly stored and available to other users
14 days ago in OpenFlows FLOOD 0 Needs review

Pump plot viewer improvements

Currently, you can only select times one-by-one, which is difficult when you have a lot of times to look at. It's useful to see where on the curve the pump is operating for the entire model run rather than need to select specific times.
5 months ago in Water Distribution Products / WaterCAD 0 Future consideration

Perform computations using hydrograph peak flows

Allow for hydraulic computations to use the peak flow from hydrographs and instead of the dynamic flows generated from the hydrographs. The software StormShed (which is an allowed software for design use by WSDOT) calculates the peak flow from the...
9 months ago in OpenFlows FLOOD 1 Needs review

Customer Meter Associated Element - Physical Alternative as Default, not Demand Alternative

Currently it is extremely tedious to change the Associated Element of a Customer Meter Model Element. An unfortunate design choice during Customer Meter implementation into WaterCAD was that within the WaterCAD Schema this Attribute was assigned t...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

web-based model viewer

In our sector of the company just me had the software watergems, so it would be awesome if we had a web-based model viewer just to share the results of the models, like pressure zones or headlosses. It would be an huge step for us, we also could u...
about 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

Globally edit pipe material and associated properties

When globally editing pipe material in WaterCAD (using flextables -->pipe), the current option allows you to type in the name of the material, but the associated pipe properties are not updated. It would be convenient if you could globally edit...
7 months ago in Water Distribution Products / WaterCAD 0 Future consideration

VSP Battery controls bug

If I create controls for a VSP Battery element, close the controls dialog, then try to edit the controls by clicking the [...] in the VSP battery properties window, no controls will show up. The controls are visible in the full controls window. Se...
5 months ago in Water Distribution Products / WaterCAD 0 Planned

Resizeable color coding properties dialog

Sometimes you need to color code by a field that has long values or a lot of values. The color coding properties dialog lets you resize the columns in the table, but doesn't let you resize the window, making it difficult to work with.
5 months ago in Water Distribution Products / WaterCAD 0 Needs review

Put the laterals and taps adjacent to each other in the element symbology TOC

I usually need to turn laterals and taps on or off at the same time, so it would be helpful to have them next to each other to make it easier to do without scrolling.
5 months ago in Water Distribution Products / WaterCAD 0 Needs review

Element symbology improvement

When you have a bunch of annotations and color coding for each element type, it becomes hard to differentiate the sections. It would be nice if there was an easier way to distinguish the element types from the annotations/color coding. If the elem...
5 months ago in Water Distribution Products / WaterCAD 0 Needs review