[Copy] Openroads Drainage - HGL versus Headwater Analysis for Headwalls Inletting into a Storm Sewer System

Many times, a stream needs to be drained into a storm sewer system via a headwall. When this occurs, two analysis should be considered: The headwater at the headwall (the mechanics of the water getting into the pipe at the headwall). Generally K...
10 months ago in Storm and Sewer Products 0 Needs review

[Copy] Add ability to set default Engineering Libraries for all users

As it stands, I can make a new Engineering Library on a network drive to share with other users, but if I wanted to make that library the "default", I can't without having to make the change for each individual user.
10 months ago in Storm and Sewer Products 0 Needs review

[Copy] Calculation Summary ("Report") Improvement Suggestions

The calculation executive summary and calculation detailed summary would be improved by adding a time stamp near the date and file name at the bottom of the reports' pages. It would be helpful to be able to add a note to the reports describing tha...
10 months ago in Storm and Sewer Products 0 Needs review

Calculate the difference between the conduit invert stop and the downstream manhole invert level (Add a new field in conduit properties)

it will be useful for whom want to know if a weir is required to be added into the downstream manhole (in case the manhole has more then one weir)
over 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

StormCAD dynamic links to Civil 3D

For StormCAD it would be very helpful to also have a dynamic link between Civil 3D stormwater pipes and StormCAD pipes. We have to run two models essentially and there is a lot of translating data from one model into the other and time spend makin...
over 1 year ago in Storm and Sewer Products / StormCAD 0 Needs review

PondPack Import Catchment Areas

The most helpful thing for how I use PondPack would be the ability to import catchment areas from CAD polyline work and maybe hatches in CAD. That way when we hatch a site pervious and impervious the numbers would automatically populate a catchmen...
over 1 year ago in Storm and Sewer Products / PondPack 0 Needs review

Flowmaster Grate Interface

Provide a cleaner interface for grate inlet analysis for custom grate specs. I have struggled with using flowmaster for special grates we are using for airport applications. I have the opening area and perimeter but I cannot input custom variables...
over 1 year ago in Storm and Sewer Products / FlowMaster 0 Needs review

Maximum spread and depth results

Hello,In sewerGEMS, especially whem modelling dual-drainage system with gutters along the road, I'd like to request to get the max spread and depth results as a Property for gutters so it can be reported on in the FlexTable (without having to move...
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Flowmaster Inlet Grates

it would be helpful to be able to analyze inlets that have slanted grates that are slanted in the direction of gutter flow. These grates are commonly used in DOT design as well as private applications. Please see attachment.
over 1 year ago in Storm and Sewer Products 0 Needs review

add Grate Width in utility Property

add Grate Width in Utility Property. (See Attachment)
about 2 years ago in Storm and Sewer Products / StormCAD 0 Future consideration