Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Ideas

Showing 135 of 190

The 2D model does not recognize the assignment of LID. Implementation is suggested.

El modelo 2D no reconoce la asignación de LID. Se sugiere la implementación. Es importante simular inundaciones y verificar el comportamiento del alcantarillado al aplicar soluciones de drenaje sostenible.
over 1 year ago in Storm and Sewer Products / SewerGEMS 1 Needs review

element property interfacing upgrade

This feature should address pipes start/stop and not the manhole invert incase of a drop at the downstream manhole.
over 1 year ago in Storm and Sewer Products / SewerCAD 0 Needs review

Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
over 1 year ago in Storm and Sewer Products / SewerCAD 0 Needs review

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Grid regeneration

The message prompting before every simulation computing is ambiguous - is it necessary to regenerate grid each time I want to compute model? Probably not if the grid wasn't changed.
over 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Docking Grid Browser

It would be nice if the Grid browser could be docked on the side of the window.
over 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

add storm input formatting for atlas 14

would be nice to add the duration depth frequency data as presented in atlas 14
over 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Query Based Selection Sets - Execute in List Order - Not by Element ID Order

Query Based Selection Sets should execute queries in List Order. Currently it executes it in Element ID Order. For example if a user attempts to create a Selection Set that is the query steps of: Select all Pipes of a Certain Diameter (By Creating...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Needs review

Network Navigator - Find Isolation Valve Referenced Pipes

To the "Network Trace" Network Navigator Tools, suggest add "Find Pipes Referenced by Isolation Valves" There are use cases for where the user needs to select and edit, delete or report Pipe Elements that are Referenced by Isolation Valve Elements...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Future consideration

Critical Referenced Model Elements: Soft or Hard Deletion Lockout

Some element deletion processes will create invalid, difficult to undo and difficult for some users to diagnose issues when the element is a critical reference element to a separate elements. Examples include: Downstream pipes of Directional Eleme...
almost 2 years ago in Water Distribution Products / WaterCAD 0 Needs review