Add ft/100ft

Most jurisdictions do not allow you to go more than 400-600 feet between manholes. Most hydraulic books and schooling uses ft/100ft for that reason. Please add the option of having ft/100ft for slope of conduits as a reportable units.
over 1 year ago in Storm and Sewer Products / SewerCAD 0 Needs review

C# API Documentation for SewerGEMS

Please develop documentation for the C# API for SewerGEMS similar to what already exists for WaterGEMS.
over 1 year ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Grid regeneration

The message prompting before every simulation computing is ambiguous - is it necessary to regenerate grid each time I want to compute model? Probably not if the grid wasn't changed.
over 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Docking Grid Browser

It would be nice if the Grid browser could be docked on the side of the window.
over 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

add storm input formatting for atlas 14

would be nice to add the duration depth frequency data as presented in atlas 14
over 3 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

Modelling Submersible Pumps - Vertical Pipe Section

The majority of new development sewage pumping stations include submersible pumps. I would like if there was a better way to input vertical pipe data, as well as be able to more accurately display the vertical pipes on the profile view.
over 1 year ago in Water Distribution Products / HAMMER 0 Needs review

SCS dimensionless curves for different durations

I advise to include the possibility for SCS dimensionless curves for 6 and 12 hours events instead of only 24 hours as per current OpenFlows products.
almost 2 years ago in Storm and Sewer Products / SewerGEMS 0 Needs review

2d module hot file

For 2d calculation, the option for hot start should be added, especially that this kind of calculations takes long time.
almost 2 years ago in Storm and Sewer Products / SewerGEMS 0 Future consideration

Built-in tool to graphically display custom turbine curves / characteristics in HAMMER.

Tool to display custom turbine curves / characteristics in hill chart form or otherwise, to allow checking input data for correctness, accuracy, sense. To assist in diagnosing issues when using custom turbine curves. To allow comparing different t...
almost 2 years ago in Water Distribution Products / HAMMER 0 Future consideration

Model a 'dynamic combination air valve'

ARI has a valve that they call a 'dynamic combination air valve'. See here for details: https://www.arivalves.com/products/water-supply/item/d-070-dynamic-combination-air-valve This is similar to HAMMER's slow closing air valve, but only starts to...
over 2 years ago in Water Distribution Products / HAMMER 1 Planned